Loading...
1955-2648RCSOLUTION NO. 2648 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ANAHEIM FINDING AND DETERMINING THAT THE PURCHASE OF CONCRETE STEEL CYLIN- DER PIPE AND FITTINGS IS NECESSARY FOR THE WATER DEPARTMENT, APPROVING THE SPECIFICA- TIONS THEREOF, AND DIRECTING PUBLICATION OF NOTICE INVITING BIDS FOR THE FURNISHING OF SAID PIPE AND FITTINGS. WHEREAS, the City Council does find and determine that public convenience and necessity require the purchase and acquisition of reinforced concrete steel cylinder pipe and fittings, including rubber gaskets for installation, for use by the Water Department of the City, in the amounts hereinafter specified; and WHEREAS, the City Council does further find that the specifications of such pipe and fittings should be fixed and determined; and WHEREAS, the City Council does find and determine that notice should be published inviting bids for the fur- nishing of pipe and fittings in the amounts and in accord- ance with the specifications hereinafter set forth; NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Anaheim that all reinforced concrete steel cylinder pipe and fittings purchased by and furnished to the City of Anaheim shall conform to and comply with "Interim Federal Specification." Pipe: Pressure, reinforced, con- crete, pretensioned reinforcement (steel cylinder type) No. SS -P -00381 GSA -FSS) issued April 2, 1953 and modified by the following: Pipe shall be Class 150 for 150 pounds maximum water working pressure. The reinforced concrete pipe may be furnished in either of two types: Pretensioned or Non- Pretensioned. When non- pretensioned pipe is furnished under this modification of the specification, it shall be the type known as steel cylinder, cement lined and coated, with the features indicated below: The design for internal pressure shall be based entirely on the steel cylinder and shall not be dependent upon any added reinforcement intended to extend the design strength of the cylinder. Such pipe shall have the bell and spigot formed integrally with the steel cylinder. The bell shall be ap eroximately four inches deep and have a flared lip to facilitate assembly. Bell thickness shall be no less than 3/16" and shall be reinforced as necessary. The spigot shall have a specially rolled groove with double "shoulders" such that after field joining, the gasket will be completely enclosed on all sides and shall not depend on internal water pressure to aid the gasket in making a water- tight joint. The pipe shall have a 1/2" cement mortar lining and a 1" cement mortar coating. The coating shall be reinforced with a 15 -1/2 Ga. wire helically wound without tension and on a 1" pitch and placed at the approximate center of the coating. Other details for non pretensioned pipe shall conform to desirable and applicable portions of the specifications referring to pretensioned pipe; in par- ticular, but not limited to: steel for cylinders, cement, rubber gaskets, allowable steel fibre stress, test pressures and fitting design. _1_ AND BE IT FURTHER RESOLVED that there shall be pur- chased for the WaterDepartment of the City of Anaheim rein- forced concrete steel cylinder pipe and fittings, including rubber gaskets for installation, in the following approximate quantities, and the following sizes and descriptions: Item 1. 7,000 feet Item 2. 3,400 feet 18" I.D. reinforced concrete steel cylinder pipe, including rubber gaskets for installation. Item 3. Five 16" flanged connections to 16" gate valves. Item 4. Three 18" flanged connections to 18" gate valves. Item 5. Two 4" flanged outlets. Item 6. Twenty -one 6" flanged outlets. Item 7. Four 8" flanged outlets. Item 8. One Item 9. One Item 10. One 16" side outlet (on 16" line) and adapted for flanged connections. Item 11. One Item 12. 16" I.D. reinforced concrete steel cylinder pipe, including rubber gaskets for installation. 16" x 16" x 16" x 10" fabricated cross with 10" outlet and one 16" outlet adapted for flanged connections. 16" x 12" x 16" fabricated tee with 12" outlet and one 16" outlet adapted for flanged connections. 16" x 16" x 10" x 10" fabricated cross with both 10" outlets and one 16" outlet adapted for flanged connections. One 10" flanged side outlet (on 16" line). -2- Item 13. One Item 14. One Item 15. One Item 16. One 18" dished head plug on 18" line. Item 17. One Hundred 1" I.P.S. hub outlets. AND BE IT FURTHER RESOLVED that the City Clerk be, and she is hereby, authorized and directed to publish a notice in the Anaheim Bulletin, in the manner and form as required by law, inviting sealed proposals for the furnishing of said pipe and fittings above described, and directing that said sealed bids will be received up to the hour of 7 :00 o'clock P.M. on March 15, 1955. THE FOREGOING RESOLUTION is signed and approved by MB this 21st day of February, 1955. ATT;ST: M YOR OF THE CITY OF ANAHEIM. CIT`Y CLERK OF THE CITY OF ANAHEIM. STATE OF CALIFORNIA I COUNTY OF ORANGE 1 ss. CITY OF ANAHEIM (SEAL) 18" x 18" x 16" x 6" fabricated cross with 6" and 16" outlets adapted for flanged connections. 18" x 18" x 12" fabricated tee with 12" and one 16" outlet adapted for flanged connections. 18" x 16" x 12" fabricated tee with 12" outlet adapted for flanged connection. I, DENE M. WILLIAMS, City Clerk of the City of Anaheim, do hereby certify that the foregoing resolution was passed and adopted at a regular meeting of the City Council of the City of Anaheim held on the 21st day of February, 1955, by the following vote of the members thereof: AYES: COUNCILMEN: Pearson, Fry, Schutte,Wisser and Van Wagoner. NOES: COUNCILMEN: None. ABSENT: COUNCILMEN: None AND I FURTHER CERTIFY that the Mayor of the City of Anaheim signed and approved said resolution on the 21st day of February, 1955. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the seal of the City of Anaheim this 21st day of February, 1955. CITY OF THE CITY OF ANAHEIM.