1974-167MES:kw WHEREAS, the City of Anaheim did commence an action to condemn certain facilities of the Southern California Edison Company on October 31, 1972 (Case No. 197120 Orange County Superior Court); and WHEREAS, the City of Anaheim did, on December 12, 1972, enter into an agreement with the Southern California Edison Company whereby adjustments would be made for additions or removals of electrical distribution facilities subsequent to the date of inventory used as a basis for the award in said action in condemnation; and WHEREAS, certain installations and removals were, in fact, made subsequent to the date of inventory as set forth in Exhibit "A" attached hereto and incorporated by reference herein; and WHEREAS, it is mutually agreed between the City of Anaheim and the Southern California Edison Company that the value of said additions or removals is $36,254.00. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Anaheim that it authorize, and it does hereby authorize the issuance of Purchase Requisition No. 1789 to the Southern California Edison Company in the amount of $36,254.00. THE FOREGOING RESOLUTION is approved and signed by me this 9th day of April, 1974. ATTEST; RESOLUTION NO. 74R -367 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ANAHEIM AUTHORIZING PAYMENT TO SOUTHERN CALIFORNIA EDISON COMPANY FOR CERTAIN BETTER- MENTS AND IMPROVEMENTS (S.C.E.- CONDEMNATION NO. 7) s s GL�c CITY CLERK OF THE CITY OF ANAHEIM OR OF THE CIT OF AN IM (SEAL) aoloe1TQ eoueuTd Juapue.utaadng TeoTa.oeT3 ao1.oaaTQ saTlTTTlfl STATE OF CALIFORNIA COUNTY OF ORANGE ss. CITY OF ANAHEIM ABSENT: COUNCILMEN: None I, ALONA M. FARRENS, City Clerk of the City of Anaheim, do hereby certify that the foregoing Resolution No. 74R was was passed and adopted at a regular meeting of the City Co held on the 9th day of April 19 74, by the following vote of the members thereof: AYES: COUNCILMEN; Stephenson, Sneegas, Pebley, Thom and Dutton NOES: COUNCILMEN: None AND I FURTHER CERTIFY that the Mayor of the City of Anaheim approved and signed said Resolution on the 9 day of April 19 74 IN WITNESS WHEREOF, I have hereunto set my hand and affixed the seal of the City of Anaheim this 9th day of April 19 74 622e..0-14-et., )77. CITY CLERK OF THE CITY OF ANAHEIM I, ALONA M. FARRENS, City Clerk of the City of Anaheim, do hereby certify that the foregoing is the original of Resolution No. 74R -167 duly passed and adopted by the Anaheim City Council on April 9, 1974. City Clerk SOUTHERN CALIFORNIA EDISON COMPANY SUMMARY OF ADDITIONS AND REMOVALS OF ELEC R CAL DIS RI ;U ON ACILITIES LOCATED IN CERTAIN PORTIONS or THE CITY OF ANAHEIM AS COVERED BY INTERIM AGREEMENT DATED DECEMBER 8, 1972 SUPERIOR COURT CASE NO. 197120 CITY OF ANAHEIM VS. SOUTHERN CALIFORNIA EDISON COMPANY Bracket, 3 transformer mounting Rack, secondary ACCOUNT NUMBER 364 POLES AND FIXTURES Pole, wood, TFL, 30 ft. (.50 interest) 1 1 0 Pole, wood, TFL, 35 ft. (.50 interest) 4 (4) Pole, wood, TFL, 45 ft. (.67 interest) 1 (1) Pole, wood, TFL, 50 ft. (.34 interest) 5 (5) Pole, wood, TFL, 50 ft. (.53 interest) 1 1 Pole, wood, TFL, 50 ft. (.55 interest) 1 1 Pole, wood, TFL, 50 ft. (.59 interest) 3 3 Pole, wood, TFL, 50 ft. (.65 interest) 5 (5) Pole, wood, TFL, 30 ft. 1 (1) Pole, wood, TFL, 35 ft. 4 4 Pole, wood, TFL, 50 ft. 6 6 Pole, wood, TFL, 55 ft. 1 1 Pavement repair (.34 interest) 2 (2) Pavement repair (.53 interest) 1 1 Pavement repair (.59 interest) 1 1 Crossarm, wood, single, 8 ft. wood pin 1 (1) Crossarm, wood, single, 8 ft. steel pin 1 1 0 Crossarm, wood, single, 10 ft. steel pin 2 1 1 Crossarm, wood, single, 12 -1/2 ft. 1 1 Guy, aerial 2 (2) Guy, down, 9/32 in. 3 1 2 Guy, down, 5/16 in. 1 (1) Anchor, steel plate, 10 ft. rod (.50 interest) Anchor, steel plate, 8 ft. rod Anchor, screw type Guard, PVC, guy wire Brace, alley arm, 8 ft. Bracket, transformer lead EXHIBIT "A" page 1 of 6 pages Net Installed Removed Change 4 2 2 2 2 1 1 3 1 (1) 1 (1) 1 (5) Southern California Edison Company Summary of Additions and Removals of Electrical Distribution Facilities Located in Certain Portions of the City of Anaheim as Covered by Interim Agreement Dated December 8, 1972 Superior Court Case No. 197120 City of Anaheim vs. Southern California Edison Company ACCOUNT NUMBER 364 POLES AND FIXTURES (Cont'd) Pin, insulator, wood 10 3 7 Pin, insulator, steel, 1 in. thread 3 (3) Pin, insulator, steel, 1 -3/8 in. thread 6 6 Step, pole 11 16 (5) Strip, visibility 8 10 (2) ACCOUNT NUMBER 365 OVERHEAD CONDUCTORS AND DEVICES Wire, 6 awg, bare copper Wire, 6 awg, weather resistant copper Wire, 4 awg, bare aluminum Wire, 2 awg, weather resistant aluminum Wire, 1/0 awg, weather resistant aluminum Clamp, dead -end, automatic, flexible 4 Grip, preformed 11 Clevis, dead -end 9 Switch, pole top, KPF horizontal, 12 kV Ground assembly ACCOUNT NUMBER 366 UNDERGROUND CONDUIT Riser, PVC conduit, 3 in. Riser, PVC conduit, 4 in. Enclosure, burd transformer Ground assembly page 2 of 6 pages Page 2 Net Installed Removed Change 270' 270' 480' (480') 150' 150' 450' 870' (420') 420' (420') Cable, 6 awg, aluminum triplex 80' 80' Cable, 4 awg, aluminum triplex 530' 530' Cable, 1/0 awg, aluminum triplex 165' 114s' Insulator, pin type, 4 kV 3 3 0 Insulator, pin type, 23 kV 3 (3) Insulator, pin type, 27 kV 7 7 Insulator, spool type dead -end 6 6 Insulator, suspension type, 6 in. (2 each) 3 3 30' 64' 6 (2) 11 9 1 1 2 2 30' 64' 5 5 6 6 Southern California Edison Company Summary of Additions and Removals of fTec Distribution Facilities Located in Certain Portions of the City of Anaheim as Covered by Interim Agreement Dated December 8, 1972 Superior Court Case No. 197120 City of Anaheim vs. Southern California Edison Company ACCOUNT NUMBER 367 UNDERGROUND CONDUCTORS AND DEVICES Cable, 2 -2 awg, synthetic insulated aluminum in duct, 12 kV Cable, 3-2 awg, synthetic insulated aluminum in duct, 12 kV Cable, 2 350 kcmil, synthetic insulated aluminum in duct, 1 kV Cable, 2-4/0 1 -2/0 awg, synthetic insulated aluminum in duct, 1 kV Cable, 2 -1 /0 1 -2 awg, synthetic insulated aluminum in duct, 1 kV Net Installed Removed Change 1,382' 264' 60' 625' 765' Page 3 1,382' 264' 60' 625' 765' Pothead, 2 awg, synthetic insulated cable, 1 /c, 12 kV 20 20 Switch, oil load break, 15 kV, 2 pole, 3 way 1 1 Hand hole, plastic 17 17 ACCOUNT NUMBER 368 LINE TRANSFORMERS Transformer, 1- phase, 5 kVA, 12000 120/240 V 1 (1) Transformer, I-phase, 10 kVA, 12000 120/240 V, CP 1 (1) Transformer, 1- phase, 15 kVA, 12000 120/240 V 1 1 Transformer, 1- phase, 15 kVA, 12000 120/240 V, CP 1 2 (1) Transformer, 1- phase, 25 kVA, 12000 120/240 V 3 3 Transformer, 1- phase, 25 kVA, 12000 120/240 V, CP 1 1 Transformer, 1- phase, 50 kVA, 12000- 120/240 V 1 1 Transformer, 3 150 kVA, 12000 277/480 V non switched, padmount 1 1 Transformer, 1-phase, 25 kVA, 12000 120/240 V, burd 4 4 Support, bolted transformer 4 4 0 Holder, fuse, 16 kV 2 (2) Mounting, fuse, 14.4 kV 7 7 page 3 of 6 pages Southern California Edison Company Summary of Additions and Removals of Electrical Distribution Facilities Located in Certain Portions of the City of Anaheim as Covered by Interim Agreement Dated December 8, 1972 Superior Court Case No. 197120 City of Anaheim vs. Southern California Edison Company ACCOUNT NUMBER 369 SERVICES OVERHEAD Service, Service, Service, Service, Service, Service, Service, Conduit, UNDERGROUND 3 -8 awg, weather resistant 3 -6 awg, weather resistant 3 -6 awg, weather resistant 3 -2 awg, weather resistant 6 awg, aluminum triplex 4 awg, aluminum triplex 4/0 awg, aluminum triplex HUG, 1 in., above ground Service, 2 -2 1 -4 awg, synthetic insulated aluminum, 600 V Service, 2 -1 /0 1 -2 awg, synthetic insulated aluminum, 600 V Service, 3 kcmil synthetic insulated aluminum, 600 V and 1 -4/0 awg weather resistant copper Service, 3 1-350 kcmil synthetic insulated aluminum, 600 V Service, 3 1 -500 kcmil synthetic insulated aluminum, 600 V Riser, PVC conduit, 4 in. ACCOUNT NUMBER 370 METERS Meter, Meter, Meter, Meter, Meter, Meter, watthour, watthour, watthour, watthour, watthour, watthour, 1- phase, 120 V, 15 A 1- phase, 240 V, 5 A 1- phase, 240 V, 15 A 1- phase, 240 V, 25 A 1- phase, 240 V, 30 A 1- phase, 240 V, 50 A copper copper aluminum aluminum page 4 of 6 pages Net Installed Removed Change 1 3 6 4 32 8 2 43 56 1 2 3 1 43 2 2 1 1 32 2 3 Page 4 2 (2) 5 4 32 8 (1) 2 24 0 0 0 42 1 Southern California Edison Company Summary of Additions and Removals of E e trical Distribution Facilities Located in Certain Portions of the City of Anaheim as Covered by Interim Agreement Dated December 8, 1972 Superior Court Case No. 197120 City of Anaheim vs. Southern California Edison Company ACCOUNT NUMBER 370 METERS (Cont'd) Page 5 Net Installed Removed Change Meter, demand, 1- phase, 240 V, 2.5 A 2 2 Meter, demand, 1- phase, 240 V, 30 A 1 (1) Meter, watthour, 3-phase, 120 V, 15 A 2 2 Meter, watthour, 3 phase, 240 V, 2.5 A 1 1 Meter, watthour, 3 phase, 240 V, 30 A 1 2 (1) Meter, watthour, 3 480 V, 50 A 2 1 1 Meter, demand, 3- phase, 120 V, 30 A 2 (2) Meter, demand, 3 phase, 240 V, 2.5 A 1 3 (2) Meter, demand, 3- phase, 240 V, 30 A 2 1 1 Meter, demand, 3- phase, 277 V, 2.5 A 2 2 Meter, reactive, 3 phase, 240 V, 2.5 A 1 1 Box, meter, 3 -phase 1 1 Block, test, 2 -pole, 100 A 8 2 6 Switch, test, 3 phase, 4 -wire metering 2 (2) Switch, test, 1- phase, 120/240 V, totalized metering 1 1 Cover, test switch 2 (2) Transformer, current, indoor, 200/5 A, 600 V 1 (1) Transformer, current, indoor, 400/5 A, 600 V 1 1 Transformer, current, indoor, 200/200/5, 600 V 1 (1) Transformer, phasing, 3 -wire, 240 V 1 1 ACCOUNT NUMBER 373 STREET LIGHTING AND SIGNAL SYSTEMS Controller, photo electric, w /mounting bracket 1 1 Relay, auxiliary 1 1 Wire, 6 awg, bare copper 450' 450' Wire, 4 awg, bare aluminum 110' 110' page 5 of 6 pages Southern California Edison Company Summary of Additions and Removals of Electrical Distribution Facilities Located in Certain Portions of the City of Anaheim as Covers by inter m A reement Dated December 8, 1972 Super or Court Case No. 9 0 City of Anaheim vs. Southern California Edison Company Page 6 Net Installed Removed Change ACCOUNT NUMBER 373 STREET LIGHTING AND SIGNAL SYSTEMS (Cont'd) Insulator, pin type, 13 kV 1 1 Insulator, series lamp 6 6 Clamp, dead -end, automatic, flexible 1 1 Grip, preformed 1 1 Conduit, PVC, 3/4 in. above ground 1 1 Valuation Department BAM /HLM /vg November 2, 1973 page 6 of 6 pages