150 S MAGNOLIA AVE BLDG 4Permit Types BLD ELE MEC PLM X Permit Number: BLD2019-05867 Issued: 12/21/2020 INSPECTION REQUEST LINE: (714) 765 - 4626 Quarter Section: 27 CI 200 S-�ANAHEIM---BLVD. (714) 765 - 5153 Site Address: 150 S MAGNOLIA AVE n 'uv y Legal Description: SEC 18 T 4,R 10 POR NW1/4 W11 Project Description: Seismic Upgrade: Voluntary seismic retrofit at carports at multi -family complex. (carports for units #153, 154, 156, 157, 160, 161, 253, 254, 255, 256, 2567, 258, 259, 260, 261, 262) REF BLD2019-05556 Valuation: $25,000.00 Construcion Types: VB, , Fire Sprinklered? No Total Fees paid for Permit: 341.25 People Associated with Project: Owner NASCH INVESTMENTS ANAHEIMLLC 2421 FOOTHILL BLVD STE 12G LA VERNE CA 91750 Contractor CONCRETE WEST CONSTRUCTION INC 1733 S DOUGLASS RD I ANAHEIM CA 92806 Permit Applicant AMBER ZAMORA Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Type Mechanical Fixtures Qty The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. fbld_permit_combo P�PHEIM CqC Cityof Anaheim o� i0 Building Division z > �DUn'DED �$hn Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION DATE T INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migadon Measures Do not install subfloor or pour floor slab until the follwing applicable items have been i Building Final (714 765-5153) Last Inspection-Final Only After Above Completed ' r�� I% Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sqaned7 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. & Fire) JSG Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter-(Meter will be set within 2-3 business days after approval) Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Strutt., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service ENGtegrity, Inc. STRUCTURAL OBSERVATIONREPORT FORM THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH_X_<eDAY OF -March -2021 REPORT NO. +3 PAGE NO. I OF 1 PROJECT ADDRESS STRUCTURAL OBSERVER STRUCT. OBS. PHONE NO. Arbors at Magnolia, 150 S Magnolia Ave, Anaheim Michael O'Brien, SE 949-2784328 OWNER LIC. OR REGISTRATION NO. BUILDING PERMIT NO. Ron Nasch, Fairmont Management S4468 OBSERVED STRUCTURAL ELEMENTS AND THEIR CONNECTIONS LOCATION AND PORTIONS OF BLDG. DATE ❑-FOUNDATION ❑-WALL ❑-FRAMES ❑-FLOOR FOR THE STRUCTURAL OBSERVATION. ESS ❑-FOOTINGS, SLAB & STEM WALLS ❑- CONCRETE 1:1 -STEEL 0 - MOMENT -SPECIAL CONCRETE E. 0, EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL ❑-PRESTRESSED CONCRETE SLABS ❑-MASONRY ❑-STEEL BRACED ❑-STEEL DECK 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE Z 4 a S 8 F-1 -CAISSONS, PILES, GRADE BEAMS ®-WOOD 1:1 -CONCRETE- ®-WOOD DUCTILE OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION OF ALL OBSERVED ❑-HILLSIDE BLDGS-SPECIAL FOUNDATION ANCHORS ❑- ❑-CONCRETE- 0 - NON -DUCTILE DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. 6. 1 HAVE PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF TF E] -PT Slab ❑- E] - SIGNED�.�OF March 202 AT_Lake Forest, CA SIGNED A' .- te.1 ja-F d ke 7r4/c. // e,�• B ! - m F J-.,4 occ r k 1 91 s - F-aNI,»� co --10 4 �t ��� F-1 DEFICIENCIES CONTINUED ON ATTACHED FORM (B&S 261 A) I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF: I. 1 AM THE REGISTERED ENGINEER OR LICENSED ARCHITECT WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. ESS 2. I, OR ANOTHER REGISTERED ENGINEER OR LICENSED ARCHITECT WHO I HAVE DESIGNATED 9?,OF /p ABOVE AND IS UNDER MY RESPONSIBLE CHARGE, HAS PERFORMED THE REQUIRED SITE VISITS AT E. 0, EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL t�Q� �D,!j�- cry CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS; 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE Z 4 a S 8 INDICATED ABOVE; m 4. 1 UNDERSTAND THAT FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY THE DEPARTMENT OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION OF ALL OBSERVED EXP. 12/31/2022 DEFICIENCIES. 5. 1 AM RESPONSIBLE FOR THE SUBMISSION OF THE ORIGINAL OF THIS REPORT TO THE SST P Q' DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. 6. 1 HAVE PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF TF THE CITY OF Anaheim OF CA` )FOS 2.)l SIGNED�.�OF March 202 AT_Lake Forest, CA SIGNED _ DAY MOMH EAR CITY X STAMP OF ENGINEER OR ARCHITECT WET SIGNATURE OF REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT STRUCTURAL OBSERVATION DOES NOT WAIVE ANY OF THE REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THIS DEPARTMENT DISTRIBUTION: STRUCTURAL OBSERVER TO SEND ORIGINAL TO THE BUILDING INSPECTOR'S OFFICE, ATTACH THE FIRST COPY TO THE APPROVED PLANS, AND KEEP SECOND COPY FOR STRUCTURAL OBSERVER'S RECORD AND DISTRIBUTIONS. ENGte-aritv. Inc. STRUCTURAL OBSERVATION REPORT FORM REPORT NO._1 THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH_1_DAY OF_February_2021 PAGE NO. 1 OF 1 PROJECT ADDRESS STRUCTURAL OBSERVER STRUCT. OBS. PHONE NO. Arbors at Magnolia, 150 S Magnolia Ave, Anaheim Michael O'Brien, SE 949-2784328 OWNER LIC. OR REGISTRATION NO. BUILDING PERMIT NO. Ron Nasch, Fairmont Management 54468 OBSERVED STRUCTURAL ELEMENTS AND THEIR CONNECTIONS OBSERVATIONS: LOCATION AND PORTIONS OF BLDG. DATE ❑-FOUNDATION ❑-WALL 0 -FRAMES 0 -FLOOR FOR THE STRUCTURAL OBSERVATION. ❑-FOOTINGS, SLAB & STEM WALLS ❑- CONCRETE ❑-STEEL F -1 - MOMENT -SPECIAL CONCRETE S%Nq EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL ❑-PRESTRESSED CONCRETE SLABS ❑-MASONRY 1:1-STEELBRACED E] -STEEL DECK 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE E] -CAISSONS, PILES, GRADE BEAMS ®-WOOD 0 -CONCRETE- ®-WOOD DUCTILE • 4468 M OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION ❑-HILLSIDE BLDGS-SPECIAL FOUNDATION ANCHORS ❑- E] -CONCRETE- E]_ NON -DUCTILE DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. E] -PT Slab ❑- - El- OBSIE�RV TIONS: I 1 /o c tL l L *3 , - -P,-A 6,,,l L4r, Ar 43. -4 1, fl -e_ -Al S 5 Qrw9 s F— DEFICIENCIES CONTINUED ON ATTACHED FORM (B&S 261 A) I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF: I. I AM THE REGISTERED ENGINEER OR LICENSED ARCHITECT WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. 2. 1, OR ANOTHER REGISTERED ENGINEER OR LICENSED ARCHITECT WHO I HAVE DESIGNATED ABOVE AND IS UNDER MY RESPONSIBLE CHARGE, HAS PERFORMED THE REQUIRED SITE VISITS AT S%Nq EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL �op�OF.c CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS; c 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE; 4. I UNDERSTAND THAT FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY THE DEPARTMENT OF ALL OBSERVED • 4468 M OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION ...1 DEFICIENCIES. 5. I AM RESPONSIBLE FOR THE SUBMISSION OF THE ORIGINAL OF THIS REPORT TO THE EXR 12131120 DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. 6. I HAVE PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF Anaheim..^T��P��\� SIGNED--I—OF—Fe 2021 , AT_Lake Forest, CA M CITY X STAMP OF ENGINEER OR ARCHITECT WET SIGNATURE OF REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT STRUCTURAL OBSERVATION DOES NOT WAIVE ANY OF THE REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THIS DEPARTMENT DISTRIBUTION: STRUCTURAL OBSERVER TO SEND ORIGINAL TO THE BUILDING INSPECTOR'S OFFICE, ATTACH THE FIRST COPY TO THE APPROVED PLANS, AND KEEP SECOND COPY FOR STRUCTURAL OBSERVER'S RECORD AND DISTRIBUTIONS. ENGtevuritp. Inc. STRUCTURAL OBSERVATIONREPORT FORM REPORT NO. Z THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH—lei DAY OF_February_2021 PAGE NO. I OF 1 PROJECT ADDRESS STRUCTURAL OBSERVER STRUCT. OBS. PHONE NO. Arbors at Magnolia, 150 S Magnolia Ave, Anaheim Michael O'Brien, SE 949-2784328 OWNER LIC. OR REGISTRATION NO. BUILDING PERMIT NO. Ron Nasch, Fairmont Management S4468 OBSERVED STRUCTURAL ELEMENTS AND THEIR CONNECTIONS LOCATION AND PORTIONS OF BLDG. DATE 0 -FOUNDATION ❑-WALL ❑-FRAMES E] -FLOOR FOR THE STRUCTURAL OBSERVATION. ❑-FOOTINGS, SLAB & STEM WALLS ❑- CONCRETE 0 -STEEL 0_ MOMENT -SPECIAL CONCRETE � SIOVE CONSTRUCTION O VERIFY IF THE ❑-PRESTRESSED CONCRETE SLABS 0 -MASONRY 11-STEELBRACED 0 -STEEL DECK INDICATED ABOVE; m ❑-CAISSONS, PILES, GRADE BEAMS ®-WOOD E] -CONCRETE- ®-WOOD DUCTILE DEFICIENCIES. ❑HILLSIDE BLDGS-SPECIAL FOUNDATION ANCHORS ❑- ❑-CONCRETE- F_ NON -DUCTILE DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. 6. I HAVE PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF s]��C,```�P [-]-PT Slab ❑- ❑- SIGNED_10_OF Feb 2021 , T_Lake Forest, CA _ OBSERVA IONS: tg� - ( L3 � mn�- b�� �� i - olywo� �a���, � I.,ir a'� -r Y "):?-- •L Ca R DEFICIENCIES CONTINUED ON ATTACHED FORM (B&S 261 A) I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF: I. I AM THE REGISTERED ENGINEER OR LICENSED ARCHITECT WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. 2. I, OR ANOTHER REGISTERED ENGINEER OR LICENSED ARCHITECT WHO I HAVE DESIGNATED _nF510 N,qI� URRE IS NU GENERAL VISITS AT IS UNDER LE CHARGE, HAS PERFORMEDTHE EACH GINVIFICANT STAGE � SIOVE CONSTRUCTION O VERIFY IF THE CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS; 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE; m 4. I UNDERSTAND THAT FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY THE DEPARTMENT OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION OF ALL OBSERVED DEFICIENCIES. C 12��2,11r� 5. I AM RESPONSIBLE FOR THE SUBMISSION OF THE ORIGINAL OF THIS REPORT TO THE E-0, DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. 6. I HAVE PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF s]��C,```�P THE CITY OF Anaheim.. lrT v OF ��\�O� SIGNED_10_OF Feb 2021 , T_Lake Forest, CA _ DAY M YE CITY x STAMP OF ENGINEER OR ARCHITECT WET SIGNATURE OF REGISTE D &VTL OR GINEER OR LICENSED ARCHITECT STRUCTURAL OBSERVATION DOES NOT WAIVE ANY OF THE REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THIS DEPARTMENT DISTRIBUTION: STRUCTURAL OBSERVER TO SEND ORIGINAL TO THE BUILDING INSPECTOR'S OFFICE, ATTACH THE FIRST COPY TO THE APPROVED PLANS, AND KEEP SECOND COPY FOR STRUCTURAL OBSERVER'S RECORD AND DISTRIBUTIONS. ENGtegrity, Inc. STRUCTURAL OBSER VA TION REPORT FORM REPORT NO. 2 THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH-1—DAY OF—March-2021 PAGE NO. 1 OF 1 PROJECT ADDRESS STRUCTURAL OBSERVER STRUCT. OBS. PHONE NO. Arbors at Magnolia, 150 S Magnolia Ave, Anaheim Michael O'Brien, SE 949-2784328 OWNER LIC. OR REGISTRATION NO. BUILDING PERMIT NO. Ron Nasch, Fairmont Management S4468 OBSERVED STRUCTURAL ELEMENTS AND THEIR CONNECTIONS LOCATION AND PORTIONS OF BLDG. DATE ❑-FOUNDATION ❑-WALL 0 -FRAMES ❑-FLOOR FOR THE STRUCTURAL OBSERVATION. ❑-FOOTINGS, SLAB & STEM WALLS ❑- CONCRETE E] -STEEL FT MOMENT -SPECIAL CONCRETE Q E O F� GENERAL ❑-PRESTRESSED CONCRETE SLABS E] -MASONRY 11-STEELBRACED ❑-STEEL DECK 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE S m ❑-CAISSONS, PILES, GRADE BEAMS ®-WOOD ❑-CONCRETE- ®-WOOD DUCTILE OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION OF ALL OBSERVED ❑-HILLSIDE BLDGSSPECIAL FOUNDATION ANCHORS ❑- 0 -CONCRETE- ❑- NON -DUCTILE 5. 1 AM RESPONSIBLE FOR THE SUBMISSION OF THE ORIGINAL OF THIS REPORT TO THE ❑-PT Slab ❑- i ❑- 9%F THE CITY OF Anaheim.. OBSERVATIONS: MFS s F-1 DEFICIENCIES CONTINUED ON ATTACHED FORM (B&S 261 A) I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF: 1. 1 AM THE REGISTERED ENGINEER OR LICENSED ARCHITECT WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. 2. I, OR ANOTHER REGISTERED ENGINEER OR LICENSED ARCHITECT WHO I HAVE DESIGNATED Q��F ESS /0 �( ABOVE AND IS UNDER MY RESPONSIBLE CHARGE, HAS PERFORMED THE REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERY IF THE STRUCTURE IS IN IF Q E O F� GENERAL CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS; CO 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE S m INDICATED ABOVE; r„ 4. 1 UNDERSTAND THAT FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY THE DEPARTMENT OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION OF ALL OBSERVED E /3 DEFICIENCIES. 5. 1 AM RESPONSIBLE FOR THE SUBMISSION OF THE ORIGINAL OF THIS REPORT TO THE DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. p 6. I HAVE PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF 9%F THE CITY OF Anaheim.. OF CA` SIGNEDI_OF_ ch 21, AT Lake Forest, CA _ D NTH CITY is STAMP OF ENGINEER OR ARCHITECT WET SICNATUPE OF REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT STRUCTURAL OBSERVATION DOES NOT WAIVE ANY OF THE REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THIS DEPARTMENT DISTRIBUTION: STRUCTURAL OBSERVER TO SEND ORIGINAL TO THE BUILDING INSPECTOR'S OFFICE, ATTACH THE FIRST COPY TO THE APPROVED PLANS, AND KEEP SECOND COPY FOR STRUCTURAL OBSERVER'S RECORD AND DISTRIBUTIONS. ENGIeeri, Inc. STRUCTURAL OBSERVATIONREPORT FORM REPORT NO. 3 THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH 3 DAY OF—March-2021 PAGE NO. 1_OF I PROJECT ADDRESS STRUCTURAL OBSERVER STRUCT. OBS. PHONE NO. Arbors at Magnolia, 150 S Magnolia Ave, Anaheim Michael O'Brien, SE 949-2784328 OWNER LIC. OR REGISTRATION NO. BUILDING PERMIT NO. Ron Nasch, Fairmont Management S4468 OBSERVED STRUCTURAL ELEMENTS AND THEIR CONNECTIONS LOCATION AND PORTIONS OF BLDG. DATE ❑-FOUNDATION ❑-WALL ❑-FRAMES 0 -FLOOR ❑-FOOTINGS, SLAB &STEM WALLS ❑- CONCRETE ❑-STEEL El - MOMENT -SPECIAL CONCRETE Q?,OF /p �� ❑-PRESTRESSED CONCRETE SLABS 0 -MASONRY E] -STEEL BRACED ❑-STEEL DECK Q�- ❑-CAISSONS, PILES, GRADE BEAMS ®-WOOD E] -CONCRETE- ®-WOOD DUCTILE y 8 S 8 ❑-HILLSIDE BLDGS-SPECIAL FOUNDATION ANCHORS ❑- ❑-CONCRETE- ❑- NON -DUCTILE EI -PT Slab ❑- El - Hip OBSERVATIONS: Bldg #1 - footings at ends of shearwalls are ready to pour concrete F— DEFICIENCIES CONTINUED ON ATTACHED FORM (B&S 261 A) I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF: 1. 1 AM THE REGISTERED ENGINEER OR LICENSED ARCHITECT WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. ESS 2. ],OR ANOTHER REGISTERED ENGINEER OR LICENSED ARCHITECT WHO I HAVE DESIGNATED Q?,OF /p �� ABOVE AND IS UNDER MY RESPONSIBLE CHARGE, HAS PERFORMED THE REQUIRED SITE VISITS AT O � E. 0,F EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IFTHE STRUCTURE IS 1N GENERAL Q�- CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS; h� V� 3. ALL DEFICIENCIES WHICH I DOCUMENTED HAVE BEEN CORRECTED UNLESS OTHERWISE y 8 S 8 INDICATEDABOVE; m 4. 1 UNDERSTAND THAT FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY THE DEPARTMENT OF BUILDING AND SAFETY CANNOT OCCUR WITHOUT THE CORRECTION OF ALL OBSERVED EXP. 12/31/2022 'k DEFICIENCIES. 5. 1 AM RESPONSIBLE FOR THE SUBMISSION OF THE ORIGINAL OF THIS REPORT TO THE Hip DEPARTMENT OF BUILDING AND SAFETY, CITY OF Anaheim. PROVIDED STRUCTURAL STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE REQUIREMENTS OF R(�C-� V�\P TF THE CITY OF VI pF CAIiF��` SIGNED 3 OF March 2021, AT—Lake Forest, CA -BAY— MONTH YEAR Cm X STAMP OF ENGINEER OR ARCHITECT WET SIGNATURE OF REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT STRUCTURAL OBSERVATION DOES NOT WAIVE ANY OF THE REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THIS DEPARTMENT DISTRIBUTION: STRUCTURAL OBSERVER TO SEND ORIGINAL TO THE BUILDING INSPECTOR'S OFFICE, ATTACH THE FIRST COPY TO THE APPROVED PLANS, AND KEEP SECOND COPY FOR STRUCTURAL OBSERVER'S RECORD AND DISTRIBUTIONS Branco 74054 San Marino Circle Palm Desert, Ca 92260 Mobile (949) 264-3199 INSPECTION REPORT PAGE 1 OF 1 PROJECT NAME Soft -Story Seismic Retrofit ADDRESS 150 S. Magnolia Ave. Anaheim, CA 92804 Building #4 ARCHITECT Engtegrity ENGINEER Micheal O'Brien CONTRACTOR Concrete West Construction, INC. OTHER Nolasco Welding Services INSPECTION DATE 3/25/21 PLAN FILE/OTHER City BLDG. PERMIT/OTHER Bldg 2019-05867 MATERIAL SAMPLING ❑ CONCRETE ❑ MORTAR ❑ GROUT ❑ FIREPROOFING ❑ MASONRY BLOCK ❑ REINFORCING STEEL ❑ STRUCTURAL STEEL ❑ BOLTS ❑ OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE -INSPECTION, TESTING, OR OTHER PROJECT ISSUES. Arrived on job site on time as requested to perform observation/inspection of : Epoxy process of #5 dowels to existing footings at columns A5 A6 A7 A8 with 6" embedment @12" o.c per detail 5/SD1 Epoxy process of #6 dowels matching tie beam t&b reinforcement with6" embedment per detail 6/SD1 Epoxy process of 3/4" all threaded anchor bolts to existing footings with 14" embedment per 3/SD1 at baseplates A5 A6 A7 A8. Epoxy process of #3 dowels to existing slab with 4" embedment at 16" o.c from lines A4 to A9 Holes were wire brushed clean and blown out with compressed air. Hilti Hit-HY epoxy was used. Placement of Quickrete precision no shrink grout with minimum 1" thickness beneath column base plates at A5 A6 A7 A8 per detail 5/ SD1. Work for today is complete andoverall work is in progress. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME Antonio Miranda Time Charge 4 hrs CERTIFICATION NO. SI 82019-00048 SIGNATURE Superintendent Cody Wienke Mi4 JOB NO, REPORT NO. INSPECTION MATERIAL IDENTIFICATION ❑ CONCRETE CONC. MIX NO. & Ib/int ❑ REINF. STEEL GROUT MIX NO. & Ib/int ❑ MASONRY MORTAR TYPE & Ib/int ❑ P.T. CONCRETE REINF. STEEL GR./SIZE ❑ FIELD WELDING STRUCTURAL STEEL ❑ SHOP WELDING HIGH-STRENGTH BOLT ❑ BATCH PLANT MASONRY BLOCK ❑ EXP. ANCHOR OTHER ✓❑ OTHER Epoxy MATERIAL SAMPLING ❑ CONCRETE ❑ MORTAR ❑ GROUT ❑ FIREPROOFING ❑ MASONRY BLOCK ❑ REINFORCING STEEL ❑ STRUCTURAL STEEL ❑ BOLTS ❑ OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE -INSPECTION, TESTING, OR OTHER PROJECT ISSUES. Arrived on job site on time as requested to perform observation/inspection of : Epoxy process of #5 dowels to existing footings at columns A5 A6 A7 A8 with 6" embedment @12" o.c per detail 5/SD1 Epoxy process of #6 dowels matching tie beam t&b reinforcement with6" embedment per detail 6/SD1 Epoxy process of 3/4" all threaded anchor bolts to existing footings with 14" embedment per 3/SD1 at baseplates A5 A6 A7 A8. Epoxy process of #3 dowels to existing slab with 4" embedment at 16" o.c from lines A4 to A9 Holes were wire brushed clean and blown out with compressed air. Hilti Hit-HY epoxy was used. Placement of Quickrete precision no shrink grout with minimum 1" thickness beneath column base plates at A5 A6 A7 A8 per detail 5/ SD1. Work for today is complete andoverall work is in progress. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME Antonio Miranda Time Charge 4 hrs CERTIFICATION NO. SI 82019-00048 SIGNATURE Superintendent Cody Wienke Mi4 Branco 74054 San Marino Circle Palm Desert, Ca 92260 Mobile (949) 264-3199 INSPECTION REPORT PAGE 1 OF 1 JOB NO. REPORT NO. PROJECT NAME Soft -Story Seismic Retrofit INSPECTION MATERIAL IDENTIFICATION ADDRESS 150 S. Magnolia Ave. ❑ CONCRETE CONC. MIX NO. & Ib/int Anaheim, CA 92804 Building #4 ❑ REINF. STEEL GROUT MIX NO. & Win ARCHITECT Engtegrity ❑ MASONRY MORTAR TYPE & Ib/int ENGINEER Micheal O'Brien ❑ P.T. CONCRETE REINF. STEEL GR./SIZE CONTRACTOR Concrete West Construction, INC. ❑✓ FIELD WELDING STRUCTURAL STEEL OTHER Nolasco Welding Services ❑ SHOP WELDING HIGH-STRENGTH BOLT INSPECTION DATE 3/24/21 ❑ BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER City ❑ EXP. ANCHOR OTHER BLDG. PERMIT/OTHER Bldg 2019-05867 ❑ OTHER MATERIAL SAMPLING ❑ CONCRETE ❑ MORTAR ❑ GROUT ❑ FIREPROOFING ❑ MASONRY BLOCK ❑ REINFORCING STEEL ❑ STRUCTURAL STEEL ❑ BOLTS ❑ OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE -INSPECTION, TESTING, OR OTHER PROJECT ISSUES. Arrived on job site on time as requested to perform observation/inspection of : 1/4" 3"@12" o.c fillet welds of continuous plate to new W beam bottom flange to existing beam on one side as per detaill /SD3 from lines A5 through A8 of building #4. Flare bevel groove welds of #4 rebar to W column flanges @ A5 through A8 of building 4 per detail3/SD2 alternative connection. Welds were visually acceptable to the applicable codes. Work for today is complete and over all work is in progress. Welder: Sergio Garcia. Process: FCAW NR 232.072" E71T 8 Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME Antonio Miranda Time Charge 8 hrs CERTIFICATION NO. SI 82019-00048 SIGNATURE Superintendent Cody Wienke �Tial& Branco 74054 San Marino Circle Palm Desert, Ca 92260 Mobile (949) 264-3199 INSPECTION REPORT PROJECT NAME Soft -Story Seismic Retrofit ADDRESS 150 S. Magnolia Ave. Anaheim, CA 92804 Building #4 ARCHITECT Engtegrity ENGINEER Micheal O'Brien CONTRACTOR Concrete West Construction, INC. OTHER Nolasco Welding Services INSPECTION DATE 3/23/21 PLAN FILE/OTHER City BLDG. PERMIT/OTHER Bldg 2019-05867 PAGE 1 JOB NO, REPORT NO. OF 1 INSPECTION MATERIAL IDENTIFICATION ❑ CONCRETE CONC. MIX NO. & Win ❑ REINF. STEEL GROUT MIX NO. & Ib/int ❑ MASONRY MORTAR TYPE & Ib/int ❑ P.T. CONCRETE REINF. STEEL GR./SIZE ❑✓ FIELD WELDING STRUCTURAL STEEL ❑ SHOP WELDING HIGH-STRENGTH BOLT ❑ BATCH PLANT MASONRY BLOCK ❑ EXP. ANCHOR OTHER ❑ OTHER MATERIAL SAMPLING ❑ CONCRETE ❑ MORTAR ❑ GROUT ❑ FIREPROOFING ❑ MASONRY BLOCK ❑ REINFORCING STEEL ❑ STRUCTURAL STEEL ❑ BOLTS ❑ OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE -INSPECTION, TESTING, OR OTHER PROJECT ISSUES. Arrived on job site on time as requested to perform observation/inspection of : 1/4" 3"@12" o.c fillet welds of continuous plate to new W beam bottom flange to existing beam on one side as per detaill/SD3 from lines A5 through A8 of building #4. Welds were visually acceptable to the applicable codes. Work for today is complete and over all work is in progress. Welder: Sergio Garcia. Process: FCAW NR 232.072" E71T 8 Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME Antonio Miranda Time Charge 8 hrs CERTIFICATION NO. SI R2019-00048 SIGNATURE Superintendent Cody Wienke P 14 Branco 74054 San Marino Circle Palm Desert. Ca 92260 Mobile (949) 264-3199 INSPECTION REPORT PAGE 1 OF 1 JOB NO. REPORT NO. PROJECT NAME Soft -Story Seismic Retrofit INSPECTION MATERIAL IDENTIFICATION ADDRESS 150 S. Magnolia Ave. ❑ CONCRETE CONC. MIX NO. & Ib/int Anaheim, CA 92804 Building #4 ❑ REINF. STEEL GROUT MIX NO. & Ib/in 2 ARCHITECT Engtegrity ❑ MASONRY MORTAR TYPE & Ib/int ENGINEER Micheal O'Brien ❑ P.T. CONCRETE REINF. STEEL GRJSIZE CONTRACTOR Concrete West Construction, INC. ❑✓ FIELD WELDING STRUCTURAL STEEL OTHER Nolasco Welding Services ❑ SHOP WELDING HIGH-STRENGTH BOLT INSPECTION DATE 3/22/21 ❑ BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER ary ❑ EXP. ANCHOR OTHER BLDG. PERMIT/OTHER Bldg 2019-05867 ❑ OTHER MATERIAL SAMPLING ❑ CONCRETE ❑ MORTAR ❑ GROUT ❑ FIREPROOFING ❑ MASONRY BLOCK ❑ REINFORCING STEEL ❑ STRUCTURAL STEEL ❑ BOLTS ❑ OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE -INSPECTION, TESTING, OR OTHER PROJECT ISSUES. Arrived on job site on time as requested to perform observation/inspection of : CJP groove welds of 2 column to beam connections as per detail 1/SD2 for moment frame to be placed at gridlines A5 and A6 of building #4. Welds were visually acceptable to the applicable codes. Work for today is complete and over all work is in progress. Welder: Sergio Garcia. Process: FCAW NR 232.072" E71 8 Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME Antonio Miranda Time Charge 8 hrs _ e� CERTIFICATION NO. SI 82019-00048 SIGNATURE Superintendent Cody Wienke // 14 REPORT OF ULTRASONIC TESTING OF WELDS Project Name 150 S Magnolia Project Nc Contract/Project Specificati, Project Specs Ultrasonic Testing Procedu AWS D1.1 -2015 Section 6 Part F Acceptance/Rejection Crite AWS DIA -2015 Table 6.2 ULTRASONIC EQUIPMENTS Page No. 2 of 2 ULTRASONIC TESTING OF MATERIALS Surface Condition Thickness Joint Type Welding Process xam from Fal a Volumetric Exam in Leg Reference Level Scanning Level Clean V Butt FCAW A/B I 1st & 2nd 66 Table 6.2 Items Examined / Testei CJP per AWS D1.1 Section 6 Table 6.2 Floor Weld ID, pc mark # gridlines, location Description Interpretation 9 weld(s ccepte Rejected Repaired Remarks A/5 Moment Connection 2 2 0 0 UTOK A/6 Moment Connection 4 4 0 0 UTOK A/7 Moment Connection 4 4 0 0 UTOK A/8 Moment Connection 2 2 0 0 UTOK Comment: u:eprw Rnru� R�p�„� wepminx Re,nw��� Total Welds 12 12 0 INDICATIONS) FOUND ON REJECTED WELDS The work Ewa: ❑was not inspected in accordance with the requirements of the approved documents. The work inspected 0 met ❑ did not meet the requirements of the approved documents. Inspector Brandon Lau Leve H Date March 23, 2021 DECIBALS (dB) DISCONTINUITY (in.) C C o c C O L„ E # __ Y c O 7 0 m = LL (e N �2 U N N N C O V c ID '° or N n. 2 E ��p C N — y c— E m m N N x W c- -JQ LL c w L � a t4 DISTANCE N v, REMARKS F¢ LL J a b c d J Q o N o a From X From Y Q U (Discontinuity Evaluation) The work Ewa: ❑was not inspected in accordance with the requirements of the approved documents. The work inspected 0 met ❑ did not meet the requirements of the approved documents. Inspector Brandon Lau Leve H Date March 23, 2021 SL INSPECTION SERVICES 1370 Valley Vista Dr Suite 200 Diamond Bar, CA 91765 1 (213)986-8224 1 www.SLinspection.biz SL.inspection@gmail.com REGISTERED INSPECTOR'S REPORT TYPE OF UT INSPECTION ❑ Reinforced Concrete ❑ Post Tensioned Concrete ❑ Structural Steel Assembly ❑ Fire Proofing ❑ Quality Control ✓❑ Non DestructiveTesting REQUIRED ❑ Reinforced Masonry ❑ Drill in Anchor/Epoxy ❑ Other Job Address: 150 S Magnolia Ave pity Anaheim Job Name: Building 4 Permit No.: Type ofstrueture: Moment Frame -Continuity Plate Architect: Engineer: Date 3/17/2021 Contractor: Inspector (s) Name: B ra n d o n Lau Subcontractor: TESTS PERFORMED TYPE OF SAMPLE SLUMP QUANTITY M SET ADDITIONAL REMARKS ON SAMPLES WELDER NAME CERT NO. WELDER NAME CERT NO. METHOD INSPECTION SUMMARY LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & INDENT. NO'S OF TEST SAMPLES TAKEN: STRUCTURAL CONNECTIONS (WELD MADE H.T. BOLTS TORQUE) CHECKED; ETC. 1) Arrived at site to perform UT on CJP 2) Calibrated UT machine for index point, angle beam, horizontal sweep, and sensitivity per AWS D1.1-2015 3) See attached report for further details -- ` _.. f _ v� pY. CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE THE ALL OF ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS, AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. SIGNATURE/ PRINT 6F REGISTERED INSPECTOR UT/MT Level II SNT-TC-1A CP -189 bf'=WALI T NU. AUtN(:T ❑✓ CONTINUED ON NEXT PAGE PAGE 1 OF 2 REG. HOURS O.T. HOURS SAMPLES 4 All inspections based on a minimum of 4 hours and over 4 hours - 8 hour minimum. In addition, any inspection extending past noon hour Will be an 8 hour minimum. Approved By r-jW Project Superintendent REPORT OF ULTRASONIC TESTING OF WELDS Project Name Building 4 Project Nit Contract/Project Specificati Project Specs Ultrasonic Testing Procedu AWS 131.1 -2015 Section 6 Part F Acceptance/Rejection Crite AWS D1.1 -2015 Table 6.2 ULTRASONIC EQUIPMENTS Page No. 2 of 2 Items Examined / Teste CJP per AWS 131.1 Section 6 Table 6.2 Floor Weld ID, pc mark # gridlines, location anufacturer Interpretation N weld(s crept Rejectec Repairec Type of B odc A/5 ng a fg. ode[ (M z) Size (in.) anal No. m onzontal inearity, Gain Control u3, Sonatest UTOK IIW Type 2 4x Continuity Plates 70 Sonatest pSS75752 2.25 .75"x.75" 1717/03 'm 9 r CL to DISTANCE 3/15/2021 in S 0111 y O' Model Type of Material Angle Mfg. e z Size Sone o. ntema Reflectors, Resolution g D 0 o Steel CX 3/15/2021 e n p ex, Angle, Distance/Sweep, Sensib aria o. Serial No. V le fg. el f Hz) Size erial o. I006746 Prior to Testing ULTRASONIC TESTING OF MATERIALS Surface Condition Thickness Joint Type Welding Process am from FaVolumetric Exam in Leg Reference Level Scanning Level Clean 1/2" T FCAW AB 1st & 2nd 66 Table 6.2 Items Examined / Teste CJP per AWS 131.1 Section 6 Table 6.2 Floor Weld ID, pc mark # gridlines, location Description Interpretation N weld(s crept Rejectec Repairec Remarks A/5 4x Continuity Plates 8 8 0 0 UTOK A/6 4x Continuity Plates 8 8 0 0 UTOK A/7 4x Continuity Plates 8 8 0 0 UTOK A/8 4x Continuity Plates 8 8 0 0 UTOK c Uf E S of ti° 'm 9 r CL to DISTANCE $ N REMARKS in S 1- ¢ ti � Q o N o a From X From Y p U (Discontinuity Evaluation) a b c d Comment Total Welds 32 32�-1 �r0 w 032'x'' �O�r IND/CATION(S) FOUND ON REJECTED WELDS The workEwa: LJ was not inspected in accordance with the requirements of the approved documents. The work inspectedE met ❑ did not meet the requirements of the approved documents. Inspecto Brandon Lau Leve II Date March 17, 2021 DECIBALS (dB) DISCONTINUITY (in.) c o c at _ o o E c Uf E S of ti° 'm 9 r CL to DISTANCE $ N REMARKS in S 1- ¢ ti � Q o N o a From X From Y p U (Discontinuity Evaluation) a b c d The workEwa: LJ was not inspected in accordance with the requirements of the approved documents. The work inspectedE met ❑ did not meet the requirements of the approved documents. Inspecto Brandon Lau Leve II Date March 17, 2021