Loading...
832 S HELENA STPermit Types BLD ELE MEC PLM X Permit Number: BLD2023-01087 Issued: 0310612023 www.anaheim.net/building (714)765.4626 Quarter Section: 74 Site Address: 832 S HELENA ST, ANAHEIM, CA 92805 Legai'Ddssc iption: N TR 1392 BLKLOT 7 AP N: 03626207 CITY OF ANAHEIM BUILDING DIVISION loo S. ANANEIIYFBLVD. (714) 765.5153 f -. .. Project Description: Reroof: Remove existing to install (20) of wood shake over entire house and (3) sq of composition shingles Living Area: Number of Stales: 0 Valuation: 10,000.00 Garage Area: Construction Types: NIA Carport Area: Occupancy Groups: Balcony I Dock Area: Fire SprMered: Cool Roos: Total Fees paid for Permit: 340.30 People Associated with Project: Contractor GIO ROOFING INC 11681/2 BROWNING BLVD202012081236447510 LOS ANGELES, CA 90037 Permit Applicant Mirian Hernandez Owner DE LA TORRE CHRISTOPHER 832 S HELENA ST Type Electrical Fixtures Oty Type Plumbing Fixtures Qly Mechanical Fixtures Qty The permit shall expire by limitation and become null and void If the building or work has not passed final Inspection 365 days from the date of permit Issuance. A new permit Is required to commence or continue work. 5 City -of Anaheim Building Division . Do not occupy this building until the final inspections have been made. Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been i ne • Building Final (714 765-5153) Last Inspection -Final Only Auer Aboa Completed Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been s' ne 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd FI of (Sheathing/Di hragmlFrame) as 99f./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Construction Exterior Plaster (Brown Coat) T -Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service BUILDING DEPARTMENT 2016 CALIFORNIA CODES 200 S. Anaheim Blvd., Suite 145 CODE CYCLE Anaheim, CA 92805 01/01/2017 714 765-5153 EFFECTIVEDATE www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION * Final inspection approval will require this completed form to be on site along with the job card. Permit Number: &02-v L?� � I6 W Date: 3 —r—� —puozo Project address: g 2 S oel w, c-4. AnaV e�m , cA qup5 Property Owner: f\o5e Cir vio de IQ fi01Q-e The undersigned does hereby certify that I am the property owner of the property. I further certify that smoke alarms and carbon monoxide alarms functional in all the following locations. All boxes must be checked below above referenced are present and Id Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. C2r Smoke Alarms: In each room used for sleeping purposes. Er Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the ,adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling units with attached garages require carbon monoxide detectors. Signature: 4Dater California Residential Code (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018 www.anaheim.net/building B842 SMOKE/ CO ALARM REQUIRED LOCATIONS Bedroom Bedroom 6 Bath 759 9 Bedroom Kitchen Living Room Figure 1 Family Room Bedroom Dining Living Room Kitchen Bedroom Bedroom Figure 2 / AgIC \ Bedroom Hall Bedroom Living Room Hall Kitchen Basement Figure 3 REQUIRED SMOKE ALARM LOCATION REQUIRED CARBON MONOXIDE ALARM LOCATION Ceilin Acceptable a• Here Never Here ���• Top of D Acceptable Here Wall Figure 4 Garage ..Ch