1182 N KNOLLWOOD CIR (5)1 Permit Types BLD ELE MEC PLM X X X X Permit Number. BLD2022-05760 Issued: 03/23/2023 CITY OF ANAHEIM www.anaheim.net/building (714)765-0626 Quarter Section: 17 j Slee Address: 1182 N KNOLLWOOD CIR, ANAHEIM, CA 92801 Legal Description: P BK 71 PG 11 PAR 27 APN: 07077209 BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765.5153 Project Description: Change of Use: 5,867 sq ft to convert existing storage space (S-2) to open office space (B) with 2,890 sq ft of converted space to be remodeled Into individual offices Luting Area: Nund)er of Stories: 1 Valuation: 130,050.00 Garage Area: Constriction Types: IIIB Carport Area: Occupancy Groups: B Balcony / Dock Area: Fire Sprinklered: Yes Cool Roof: Total Fees paid for Permit: 28,061.60 People Associated with Project: Permit Applicant Cad WayneKasalek Owner KNOLLWOOD CIRCLE LLC 1241 CAPER TREE DR Architect GENSLER 4675 MacArthur Court Newport Beach, CA 92660 Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty Apparatus or equipment not listed 1 Gas System (outlets) 1 Commercial System per 1,000 sq. ft. 6 Motors - over 10 h.p. 2 Compressor/Boller - up to 15 hp 3 Multi -outlet assembles - each W 5 (commercial) Receptacle, switches, lights 206 The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the date of permit issuance. A now permit is required to commence or continue work. P�PHElm Cq< City of Anaheim D� �o Building Division i u > SOUNDED �$yn Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test / JSG Electrical Final �G Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765-5126 INSPECTION I DATE INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 765-4591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days) Setback/FormslTrenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been s' Building Final (714 765-5153) Last Inspection-Final Only After Above Completed 71,Aj , Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections % y f-'Qz '0'/W Sk•E 4!',a(91 G Mechanical (Groundwork) Electrical (Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) '% j %aST e.**A- X-m=OE: pfF=.BALE Underfloor Insulation (Raised Foundation Only) [,q jr-A u4VaGl5F— 5,1--ALC Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been e. 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. & Fire) 30 N gg3 -j5C Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections JcSG ��s�o�3ycta w,¢l.�S s�D P�� bt.` Y Electrical Service Meter-(Meter will be set within 2-3 business days after approval) Excludes New Constructlo Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) OVA-3 of Sri Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service