Loading...
2516 E OSHKOSH AVE (3)City of Anaheim BUILDING DIVISION INSPECTION RECORD 10 SWIMMING POOL ADDRESS: 2516 E OSHKOSH AVE, ANAHEIM, CA 92806 OWNER: SALTZMAN JOHN 6 BECKY PERMIT #: SWI2016-00097 DATE ISSUED: 08/30/2016 DESCRIPTION: Pool: 580 sq.ft to reinstate expired permit number DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. #14802 built in 1964. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE spection Code Date Inspector 504 ding 506 508 PBLD-Steel Gunite 510 DO NOT GUNITE POOUSPA until all the above Inspections have been signed. nd Electric bonding (Rock Structures,Slides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. 6. Underground Electric _ 512 7. Gas Piping Test 514 8. P -Trap Receptor 516 9. Backflow 518 10. Deck, Deck Drains, Equipotential & Accessory Bondina 520 DO NOT POUR FLATWORK until all the above inspections have been signed. 11. Rough Electrical 522 12. Fencing/Door Alarms 524 G Z 13. Plaster approval 526 DO NOT PLASTER until all the above inspections have been signed. 14. Final Electric 52g,Q( Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 MISC. INSPECTIONS Date Inspector fbldjobcards Insoacdons 14: 1. A l plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. AN metal within 5 feet of pool water, and a9 pool equipment, must be bonnded to pool reinforcing steel with 08 solid copper wire. Niche light shag, deck Inserts, etc. shall be bonded to pool rebar. 3. Pod equipment is not required to be set at this time. Insoactlons 8.10: 1. Underground electric Inspected prior to backfilling. 2. Gas gne test at 100 for 15 minutes with 150 gauge. 3. When polyethylene gas ping is used, a certificate Tran a certifted Installer and tracer wire shall be provided per CPC 1210.1.72 APPENDIX 1. Inspections 1143: 1. Rough electric Inspection when all wiring Is completed and ready prior to the plastering of poollsps. Polling compound in place at plastic light niche. 2. Current Code requires that any pod, ape or water feature contacting water 18 inches or more in depth shall be enclosed by a barrier adequate to prevent entry of small children. The barrier shag comply with Section 3109 of cement CBC and CRC APPOENDIX V specifying the height of any fence provided as barrier to the pod ti- shall be 60' above grade on the outside of the fence. 3. Doors from a garage shag meet the requirements for a gets. Glass windows within F of pool water shag be tempered glass. 4. Prior to pro -plaster Inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pod or spas. 5. Grading complete with positive drainage to street or pubic way. All exposed plastic pipe shag be painted to protect from sunlight. Inspections 14.16: 1. Gas and Electrical completely removed and 2x2 holes at bottom of pod and/or Isolated elements. 2. Pod backfilled: A.) With future build - selkompacting sand 95% with receipt B.) No Nhfe build - any ill. 3. After pool Is operating and In working condillon with approved pod cover on site. Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building inspection online, please go to https://aca.anaheim.neUCidzenAccess Inspection can normally be reached between 7:30.8:00 A.M. (714)7655153 + 0 To access your inspection timeframe: Please go to www.anaheim.net/building after 7:30am on the day of your Inspection. Under Online SeMces, dick on the Ink -Inspection Timeframes- or call (714) 765.5153 + 0