Loading...
5801 E. PASEO DE LEON (2)Permit Types CITY OF ANAHEIMPLMBLDELEMEC X X BUILDING DIVISION 200 S.ANAHEIM BLVD. (714)765-5153 Permit Number:BLD2023-01265 Issued:03/24/2023 www.anaheim.net/building (714)765-4626 Quarter Section:185 Site Address:5801 E PASEO DE LEONANAHEIM,CA 92807 Legal Description:N TR 7769 BLK LOT 154 APN:36318443 Project Description:Residential Photovoltaic System with Microinverters 6,500.00Valuation: Construction Types: Occupancy Groups: Fire Sprinkiered: Total Fees paid for Permit: Number of Stories:Living Area: Garage Area: Carport Area: Balcony I Deck Area: Cool Roof:167.00 People Associated with Project: 9440 SANTA MONICA BLVD STE 301 BEVERLY HILLS,CA 90210Contractor Permit Applicant CALIFORNIA STATE DEVELOPMENT Volodymyr Kashuba Mechanical Fixtures QtyQtyQtyTypePlumbingFixturesElectricalFixturesType 15Microinverter The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance.A new permit is required to commence or continue work. FINAL INSPECTIONS DATE 'MSPECTOR City of Anaheim Building Division All applicable items below must be signed before utilities arc released Final Gas Test SOnrAfp^l’i'ciiElectricalFinal Plumbing Final Mechanical Final Cross Connection Control (714)765-4280 Do not occupy this building until the final inspections have been made.Engineering Final (714)765-5126 INSPECTION DATE INSPECTOR Fire Sprinkler (ONLY)(714)765-5041 Do not pour concrete until the following applicable items have been signed:Fire Dept.Final (714)765-5041 Plumbing (Ground/Underfloor Drain Waste)Water Engineering (714)765-4591 Sub List/Bus.Lie.(714)765-5194 (Allow 10 business days)Electrical Ground Electrode/Ufer Setback/Forms/Trenches (Footings)COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been Feigned S/llAj sfiwffjbTcBuildingFinal(714 765-5153) Last Inspection-Final Only After Above CompletedPlumbing(Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONSMechanical(Groundwork) Building InspectionsElectrical(Underground Conduit) Pre-slab (Compaction/Membrane Reinf.) Floor (Joist/Girders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the follov/ing applicable items have been cloned 1st Floor Shear Mechanical InspectionsFiresprinkler(Rough)(Fire Dept.) 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Relnf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Plumbing InspectionsRoughCOA/Mitagation Measures Framing (Only after PIbg.,Ele.,Mec.&Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele,Mec &PIbg) Interior Lath Electrical InspectionsExteriorLath Electrical Service Meter-(Meter will be set within 2-3 business days after approval)Excludes New Construction Exterior Plaster (Brown Coat) T-Bar (Struct.,Ele.,or Mec.) Grease Interceptor iPn nni liarkfill nrilPF;s sinnofl otti Sewer Water Engineering Backflow (Testable Only) Water Service \ Solar PV Standard Plan —Simplified Central/String Inverter Systems for One-and Two-Family Dwellings 9.Single-Inverter Line Diagram Single-Line Diagram for Microinverters or ACMsEquipmentSchedule A TAG DESCRIPTION:(Provide model #rf provided)Check a box for dc system grounding:□Grounded,K Ungrounded For ungrounded dc power systems,EGC is required For grounded dc power systems,GEC &EGC are required Refer to CEC 250.120 for EGC installation &Table 250.122 for sizing 1 Solar PV Module or ACM:LG360Q1C-A5 MODULES.JA SOLAR JAM72S10-400/PR MODULES 2 Microinverter (if not ACM):eNPHASE IQBPLUS-72-2-US f24QVlMCRQlNVERTERS. Junction Box (es):YES.NEMA 3R.UL LISTED 3 Solar Load Center.Yes /No:NO4 5 Performance Meter Yes /No: YES6●Utility External Disconnect Switch Yes /No:*Consult with your local AHJ and /or Utility 7 Main Electrical Service Panel EXISTING 225/200 A A (, -PV DC ->AC --[ T I b —●G|-PV DC ->AC ---[ AT H PV DC ->AC --[Branch Circuit OCPDs (Table 3) Branch 1 OCPD size 20 Branch 2 OCPD size 20 Branch 3 OCPD size Solar Load Center Busbar(Section 5) *0 Q)B IUJ L 0 *0 Main Service Panel OCPDs<DC GEC, When Required Main OCPD size:(table 5)i«l Combined Inverter Output OCPD:(Table 41^ Main Service Panel Busbar:(Table 5)225 o o 225 O Conductor,Cable and Conduit Scheduleo n (U Conductor Size Number of Conductors Conduit/Conductor/ Cable TypeTAGDescriptionandConductorType:(Table 3)Conduit Size MIN|0.75"EMT <j> o Ithwn-^<Current-Carrying Conductors:(for each branch circuit)10 2rt> EGC;A 8 13 3 GEC (when required):rt)THWN-2Current-Carrying Conductors:10 MIN 0-75"Wa EMT33 t/>EGC:B 88 to tn SOLAR PV STANDARD PLAN —SIMPLIFIED Microinverter and ACM Systems for One-and Two-Family Dwellings ROOF LAYOUT PLAN o 3 V) o a> ●D rc »ITC MOTTS {PtR xat CftCl ●ALACC£R3HAUBE!NPLA(^FORNSPECnONf4COWPUANCSVWTHOSHA REOyLMTONS *THCP^WOOIUS AKE CONSKKReD NON<OMBUSTBLe AMO THIS ST^TCMIS AN unuTY iNTPRAcrrjc «wr»u with no sroRjiap battfbip« ●TVCSOURPVINSTAUATIONSHAUNOTOBSTRUCTANYPLUUBlHa, MECHANICAL OR BUILDINO ROOF VENTS ●PROPERACeCCSANOWORKINOCIXARANCEAinOUNOCXOTINOANO PROPCSB3 EieCTRCAL EQUIPMENT WI.L BE PROVOED AS PER SECTION ICAtllUOHUkTATSlD£Vti.OPM£H OUJFORNH STATE DEVELUTHENT PH« 3 3 3 on Ct c Q. 0) O’r 56’-7'o ro STe'AMNKl.VX"C L <ni twiM H3Wu»n4>gs onV. TREES (F)PFNCP rCU< 5 tu> ^5B 'Coo rc)C*RWFCvdCD6055i.(E)MAM SERVICE PANEL 84n4d 1/140033 rsiunuTvweTtP EgROQFPl rae)AA SOLAR MAfTSSIO-MSTR WOOUlSS i_.8UJa-I KuiS g5JIs|(Nl NCM-ruaCD AC OOCONNECr O nROQPbI {03)UMWQ1C-M Wl*UUlES «cu 0>o (j 2 <o z S S >UJS9 S (/>s UJ <Aa(N)ENPHASE IQ COMBfCR 4C TB 23 S_S)i^«c●4'.g-ra: I lElORMEWAY ^ lEl PATHWAY Q»T»335> >WtT<Ul« 1 L SITE PUVNpnDPBtrruNi34'-5"r ANSID irxirEASTEASEDDELEON PLOT PLAN WITH ROOF PLAN PV-1PV.1 SCALE virBt'-<r Items required:roof layout of all panels,modules,clear access pathways and approximate locations of electrical disconnecting means and roof access points. L Permit Types BLD ELE MEC PLM X X Permit Number: BLD2023-01265 Issued: 03/24/2023 www.anaheim.net/building (714)765-0626 Quarter Section: 185 CITY OF ANAHEIM Site Address: 5801 E PASEO DE LEONANAHEIM, CA 92807 Legal Description: N TR 7769 BLK LOT 154 APN: 36318443 BUILDING DIVISION 200 S. ANAHEIM BLVD. 1714)765-5153 WORKER'S COMPENSATION DECLARATION: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST, AND ATTORNEY'S FEES. I hereby affirm under penalty of pedury one of the following declarations: I have and will maintain a certificate of consent to selfminsure for worker's compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. VK 1 have and will maintain worker's compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's Compensation insurance carrier and policy are: Cartier. STATE COMPENSATION INSURANCE FUND Policy No.: 9254239 Expiration Date: 6(17/2023 Name of Agent: Phone No.: 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers compensation laws of California, and agree that, if I should become subject to the workers compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Volodymyr Kashuba 3/24/2023 Signature of Applicant Date DECLARATION REGARDING CONSTRUCTION LENDING AGENCY: I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit Is Issued (Sec.3097.Civ.C): Lender's Name: Lender's Address: LICENSED CONTRACTOR'S DECLARATION: I hereby affirm under the penalty of Perjury that I am licensed under provisions of chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. CALIFORNIA STATE DEVELOPMENT 3/2412023 Contractor Signature Date NUMBER EXPIRATION DATE LICENSE TYPE (S) 1049108 01/31/2023