5801 E. PASEO DE LEON (2)Permit Types CITY OF ANAHEIMPLMBLDELEMEC
X X BUILDING DIVISION
200 S.ANAHEIM BLVD.
(714)765-5153
Permit Number:BLD2023-01265
Issued:03/24/2023
www.anaheim.net/building
(714)765-4626
Quarter Section:185
Site Address:5801 E PASEO DE LEONANAHEIM,CA 92807
Legal Description:N TR 7769 BLK LOT 154
APN:36318443
Project Description:Residential Photovoltaic System with Microinverters
6,500.00Valuation:
Construction Types:
Occupancy Groups:
Fire Sprinkiered:
Total Fees paid for Permit:
Number of Stories:Living Area:
Garage Area:
Carport Area:
Balcony I Deck Area:
Cool Roof:167.00
People Associated with Project:
9440 SANTA MONICA BLVD STE 301 BEVERLY HILLS,CA 90210Contractor
Permit Applicant
CALIFORNIA STATE DEVELOPMENT
Volodymyr Kashuba
Mechanical Fixtures QtyQtyQtyTypePlumbingFixturesElectricalFixturesType
15Microinverter
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit issuance.A new permit is required to commence or continue work.
FINAL INSPECTIONS DATE 'MSPECTOR
City of Anaheim
Building Division
All applicable items below must be signed before utilities arc released
Final Gas Test
SOnrAfp^l’i'ciiElectricalFinal
Plumbing Final
Mechanical Final
Cross Connection Control (714)765-4280
Do not occupy this building until the final inspections have been made.Engineering Final (714)765-5126
INSPECTION DATE INSPECTOR Fire Sprinkler (ONLY)(714)765-5041
Do not pour concrete until the following applicable items have been signed:Fire Dept.Final (714)765-5041
Plumbing (Ground/Underfloor Drain Waste)Water Engineering (714)765-4591
Sub List/Bus.Lie.(714)765-5194 (Allow 10 business days)Electrical Ground Electrode/Ufer
Setback/Forms/Trenches (Footings)COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
Feigned S/llAj sfiwffjbTcBuildingFinal(714 765-5153)
Last Inspection-Final Only After Above CompletedPlumbing(Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONSMechanical(Groundwork)
Building InspectionsElectrical(Underground Conduit)
Pre-slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the follov/ing applicable items have
been cloned
1st Floor Shear
Mechanical InspectionsFiresprinkler(Rough)(Fire Dept.)
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Relnf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Plumbing InspectionsRoughCOA/Mitagation Measures
Framing (Only after PIbg.,Ele.,Mec.&Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele,Mec &PIbg)
Interior Lath
Electrical InspectionsExteriorLath
Electrical Service Meter-(Meter will be set within 2-3
business days after approval)Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct.,Ele.,or Mec.)
Grease Interceptor
iPn nni liarkfill nrilPF;s sinnofl otti
Sewer
Water Engineering Backflow (Testable Only)
Water Service
\
Solar PV Standard Plan —Simplified
Central/String Inverter Systems for One-and Two-Family Dwellings
9.Single-Inverter Line Diagram
Single-Line Diagram for Microinverters or ACMsEquipmentSchedule
A TAG DESCRIPTION:(Provide model #rf provided)Check a box for dc system grounding:□Grounded,K Ungrounded
For ungrounded dc power systems,EGC is required
For grounded dc power systems,GEC &EGC are required
Refer to CEC 250.120 for EGC installation &Table 250.122 for sizing
1 Solar PV Module or ACM:LG360Q1C-A5 MODULES.JA SOLAR JAM72S10-400/PR MODULES
2 Microinverter (if not ACM):eNPHASE IQBPLUS-72-2-US f24QVlMCRQlNVERTERS.
Junction Box (es):YES.NEMA 3R.UL LISTED 3
Solar Load Center.Yes /No:NO4
5 Performance Meter Yes /No:
YES6●Utility External Disconnect Switch Yes /No:*Consult with your local AHJ and /or Utility
7 Main Electrical Service Panel EXISTING 225/200
A A
(,
-PV DC ->AC --[
T I
b —●G|-PV DC ->AC ---[
AT
H PV DC ->AC --[Branch Circuit OCPDs
(Table 3)
Branch 1 OCPD size 20
Branch 2 OCPD size 20
Branch 3 OCPD size
Solar Load Center
Busbar(Section 5)
*0
Q)B
IUJ
L
0
*0 Main Service Panel OCPDs<DC GEC,
When Required Main OCPD size:(table 5)i«l
Combined Inverter Output OCPD:(Table 41^
Main Service Panel Busbar:(Table 5)225
o
o
225
O
Conductor,Cable and Conduit Scheduleo
n
(U Conductor
Size
Number of
Conductors
Conduit/Conductor/
Cable TypeTAGDescriptionandConductorType:(Table 3)Conduit Size
MIN|0.75"EMT
<j>
o
Ithwn-^<Current-Carrying Conductors:(for each branch circuit)10 2rt>
EGC;A 8 13
3 GEC (when required):rt)THWN-2Current-Carrying Conductors:10 MIN 0-75"Wa EMT33
t/>EGC:B 88
to
tn
SOLAR PV STANDARD PLAN —SIMPLIFIED
Microinverter and ACM Systems for One-and Two-Family Dwellings
ROOF LAYOUT PLAN
o
3
V)
o
a>
●D
rc »ITC MOTTS {PtR xat CftCl
●ALACC£R3HAUBE!NPLA(^FORNSPECnONf4COWPUANCSVWTHOSHA
REOyLMTONS
*THCP^WOOIUS AKE CONSKKReD NON<OMBUSTBLe AMO THIS ST^TCMIS
AN unuTY iNTPRAcrrjc «wr»u with no sroRjiap battfbip«
●TVCSOURPVINSTAUATIONSHAUNOTOBSTRUCTANYPLUUBlHa,
MECHANICAL OR BUILDINO ROOF VENTS
●PROPERACeCCSANOWORKINOCIXARANCEAinOUNOCXOTINOANO
PROPCSB3 EieCTRCAL EQUIPMENT WI.L BE PROVOED AS PER SECTION
ICAtllUOHUkTATSlD£Vti.OPM£H
OUJFORNH STATE
DEVELUTHENT
PH«
3
3
3
on
Ct
c
Q.
0)
O’r 56’-7'o ro STe'AMNKl.VX"C L <ni twiM H3Wu»n4>gs onV.
TREES
(F)PFNCP
rCU<
5 tu>
^5B 'Coo
rc)C*RWFCvdCD6055i.(E)MAM SERVICE PANEL 84n4d 1/140033
rsiunuTvweTtP EgROQFPl
rae)AA SOLAR MAfTSSIO-MSTR WOOUlSS i_.8UJa-I KuiS g5JIs|(Nl NCM-ruaCD AC OOCONNECr O nROQPbI
{03)UMWQ1C-M Wl*UUlES «cu 0>o (j 2 <o z S S
>UJS9
S (/>s UJ
<Aa(N)ENPHASE IQ COMBfCR 4C TB
23 S_S)i^«c●4'.g-ra:
I
lElORMEWAY ^
lEl PATHWAY
Q»T»335>
>WtT<Ul«
1 L SITE PUVNpnDPBtrruNi34'-5"r
ANSID
irxirEASTEASEDDELEON
PLOT PLAN WITH ROOF PLAN
PV-1PV.1 SCALE virBt'-<r
Items required:roof layout of all panels,modules,clear access
pathways and approximate locations of electrical disconnecting
means and roof access points.
L
Permit Types
BLD ELE MEC PLM
X X
Permit Number: BLD2023-01265
Issued: 03/24/2023
www.anaheim.net/building
(714)765-0626
Quarter Section: 185
CITY OF ANAHEIM
Site Address: 5801 E PASEO DE LEONANAHEIM, CA 92807
Legal Description: N TR 7769 BLK LOT 154
APN: 36318443
BUILDING DIVISION
200 S. ANAHEIM BLVD.
1714)765-5153
WORKER'S COMPENSATION DECLARATION:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED
FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST, AND ATTORNEY'S FEES.
I hereby affirm under penalty of pedury one of the following declarations:
I have and will maintain a certificate of consent to selfminsure for worker's compensation, issued by the Director of Industrial Relations as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
VK
1 have and will maintain worker's compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued. My worker's Compensation insurance carrier and policy are:
Cartier. STATE COMPENSATION INSURANCE FUND Policy No.: 9254239 Expiration Date: 6(17/2023
Name of Agent: Phone No.:
1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the
workers compensation laws of California, and agree that, if I should become subject to the workers compensation provisions of Section 3700 of the
Labor Code, I shall forthwith comply with those provisions.
Volodymyr Kashuba 3/24/2023
Signature of Applicant Date
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY:
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit Is Issued
(Sec.3097.Civ.C):
Lender's Name:
Lender's Address:
LICENSED CONTRACTOR'S DECLARATION:
I hereby affirm under the penalty of Perjury that I am licensed under provisions of chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, and my license is in full force and effect.
CALIFORNIA STATE DEVELOPMENT 3/2412023
Contractor Signature Date
NUMBER EXPIRATION DATE LICENSE TYPE (S)
1049108 01/31/2023