103 S TREVOR ST (2)Permit Types
PL
BLD ELM
X E MEC
Permit Number: OLD2024-05254
Issued: 10/02/2024
wvnw.anaheim.net/building
(714)765-4626
Quarter Section: 133
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765. 5153
Site Address: 103 S TREVOR ST, Anaheim, CA 92806
Legal Descriptlon: N TR 4321 BLK LOT 37
APN: 26807221
Project Description: Reroof: Remove and install (23) squares of composition shingles over house and attached garage
Living Area: Number of Stories: 0 Valueson:
Garage Area: Construction Types:
Carport Area: Occupancy Groups:
Balcony I Deck Area: Fire Sprinklered:
Cool Roof: Total Fees paid for Permit:
15,00000
WA
360.95
People Associated with Project:
Contractor
KING ROOFING 1D44 W ORANGE ROADABCDE11144887 SANTA ANA, CA 92705
Permit Applicant
Peda Estrada
Owner
BRIDGE, JOSEPHINE M 103 STREVOR
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit Is required to commence or continue work.
PNPNEIM C7C
City of Anaheim 04 io
Building Division i
U >
pVNDEp `S9
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS DATE INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
INSPECTION
I DATE
I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 765-4591
Electrical Ground ElectrodelUfer
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
stoned
Building Final (714 765-5153)
Last Inspection -Final Only After Above Completed
^7t
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sianed
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof(SheathinglDiaphragm/Frame)
nn
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele_ Mee. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed.
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Construction
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
(Do not i unless sinned off)
Sewer
Water Engineering Backflow (Testable Only)
Water Service
C411�' OW'04/t0a:llSyl
BUILDING DEPARTMENT
200 S. Anaheim Blvd., Suite 145
Anaheim, CA 92805
714 765-5153
www.anaheim.net/building
SMOKE DETECTORS AND CARBON
Final insoection aooroval will require this com
Permit Number:
Project address:
2016 CALIFORNIA CODES
CODECYCLE
01/01/2017
EMCTn DATE
MONOXIDE SELF CERTIFICATION
ad form to be on site along with the job card.
Date: 101/DLA c/
Property Owner: ff o-sephlne e1'IGQ9 C
The undersigned does hereby certify that I am the property owner of the above referenced
'6iiL/ property. I further certify that smoke alarms and carbon monoxide alarms are present and
functional in all the following locations. All boxes must be checked below
❑ Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
Csleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
❑ Smoke Alarms: In each room used for sleeping purposes.
❑ Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units with attached garages require carbon monoxide detectors.
Signature:
/0// olae
California Residential Code (CRC) Section R314.6.2,CRC R315.2 states in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, Califomia 92805 (714)765-5153 Phone (714)765-4607 Fax FEB 2018
www.anaheim.net/building B842
SMOKE/ CO ALARM REQUIRED LOCATIONS
Bedroom Bedroom
ZBedroom
Kitchen
Living Room
Figure t
Family Room Bedroom
Dining
Living Room
Kitchen
Bedroom Bedroom
Figure 2
Figure 3
REQUIRED SMOKE ALARM LOCATION
REQUIRED CARBON MONOXIDE ALARM LOCATION
Ceifn +
Acceptable a
Here Never
Here �IT
Top of Detector
ACGeptaNe Here
Mn