819 S PRICILLA STPermit Types
BLD ELE
MEC
PLM
X
Permit Number: BLD2024-05237
Issued: 10/01/2024
www.anaheim.net/building
(714)765-4626
Quarter Section: 114
CITY OF ANAHEIM
Site Address: 819 S PRISCILLA ST, ANAHEIM, CA 92806
Legal Description: N TR 7406 BLK LOT 13
APN: 25304234 .Ai.
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714)765. 5153
1 sue,{
< 4'
Project Description: Reroof: To remove and install (9) squares of flat roof torch down cap sheet over flat portion of house only
Lving Area: Number of Stories: t Valuation:
Garage Area'. Construction Types:
Carport Area: Occupancy Groups:
Balcony / Deck Area. Fire Spnnklered:
Cool Roof: Total Fees paid for Permit:
People Associated with Project:
Contractor SUDDUTH CONSTRUCTION INC DBA GUARDIA 1010 N BATAVIA ST STE F # F 200601091041349450 ORANGE, CA 92867
Permit Applicant Evelyn Menendez
Owner IKEDA, DARREL K 819 PRISCILLA ST
7,350.00
VB
359.96
Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures City
The permit shall expire by limitation and become null and void If the building or work has not passed final inspection 365 days from the
date of permit issuance. A new permit is required to commence or continue work.
City of Anaheim
Building Division
Do not occupy this building until the final inspections have been made.
INSPECTION DATE I INSPECTOR
Do not pour concrete until the following applicable items have been signed.
Plumbing (GroundlUnderfloor Drain Waste)
Electrical Ground Electrode/Ufer
Setback/Forms/Trenches (Footings)
Do not install subfloor or pour floor slab until the follwing applicable items have been
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (Joist/Girders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
2nd Floor Shear
Roof (Sheathing/Diaohraam/Fran
(Reinf./Bond
Out)
Duct(Mech
Mechanical
Electrical
FINAL INSPECTIONS DATE INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 765-4280
Engineering Final (714) 765-5126
Fire Sprinkler (ONLY) (714) 765-5041
Fire Dept. Final (714) 765-5041
Water Engineering (714) 7654591
Sub List/Bus. Lic. (714) 765-5194 (Allow 10 business days)
COA/Migation Measures
Building Final (714 765-6153) ti Y
Last Inspection -Final Only After Above Completed \\
Building Inspections
PARTIAL INSPECTIONS
Rough COA/Mitagation Measures Plumbing Inspections
Framing (Only after Ping Ele Meg 8 Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed.
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Service Meter -(Meter will be set w
business days after approval) Excludes New
Exterior Plaster(Brow
T-Bar (Struct., Ele., or
Sewer
Water Engineering Backflow
Water Service
Electrical Inspections
Jw..a_ � -
BUILDING DIVISION
CITY OF ANAHEIM
BUILDING DEPARTMENT 2013 CALIFORNIA CODES
200 S. Anaheim Blvd., Suite 145 CODE CYCLE
Anaheim, CA 92805 01/01/2014
FFFF.CrnT MTF.
714 765-5153
www.anaheim. i ict /tcr.Idi n„
SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION
` Final inspection approval will require this completed form to be on site along with the job card.
PermitNumber: Z U> G Date:
Project address: An:� C- "//Cc
Property Owner: / J-►�/�—
The undersigned does hereby certify that I Yn the property owner of the above referenced
property. I further certify that smoke alarms and carbon monoxide alarms are present and
functional in all the following locations. All boxes must be checked below
&IF Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate
sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms.
r�< Smoke Alarms: In each room used for sleeping purposes.
j� Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement;
(Note: in dwellings or dwelling units with split levels and without an intervening door between
the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level
shall suffice for the adjacent lower level provided that the lower level is less than one full story
below the upper level.)
All dwelling units with attached garages require carbon monoxide detectors.
Signature: Date: l l
2y
California Residential Code (CRC) Section R314.6.2,CRC R315.2 States in part that existing dwellings be
"retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or
in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as
indicted above.
NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim
Inspector is not achieved during the course of project construction. It is normally used for exterior projects such
as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work.
200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax SEPT 2015
e .anaheim.net/building B842