Loading...
321 N SWEETHEART STPermit Types BLD ELE MEC PLM X X Permit Number: BLD2024-05471 Issued: 10/14/2024 www.anaheim.net/building (714)765-4626 Quarter Section: 161 CITY OF ANAHEIM Site Address: 321 N SWEETWATER ST, ANAHEIM, CA 92807 Legal Description: N TR 5826 BLK LOT 17 APN: 35910301 BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765 -5153 Project Description: Residential Photovoltaic System - Microinverters (without ESS) Living Area: Number of Stones: Valuation: 21,997.00 Garage Area: Construction Types: Carport Area: Occupancy Groups: Balcony I Deck Area: Fire Sprinklered: Cool Roof: Total Fees paid for Permit: 177.00 People Associated with Project: Contractor MY SMART HOUSE LLC 39809 AVENIDA ACACIAS STE D MURRIETA, CA Permit Applicant Jose Banana 39809 Avenida Acacias Suite D Murrieta, CA 92563 Type Electrical Fixtures Oty Type Plumbing Fixtures Qty Mechanical Fixtures Q4 Microinverter 29 The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. P. ..,"Elm -i Cityof Anaheim O� iO Building DIVI510n y > OVNO ED 9h^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE 4NSPEC30R All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 765-4280 Engineering Final (714) 765.6126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 7655041 Do not pour concrete until the following applicable items have been signed. Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 766-4591 Electrical Ground Electrode/Ufer Sub Llst/BUs. Lie. (714) 765-5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been Building Final (714 765-5153)sioned Last Inspection -Final Only After Above Completed %lffj.i Plumbing (Ground/underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (JoisUGirders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sianed 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. 8 Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed. Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor Sewer Water Engineering Backflow (Testable Only) Water Service BUILDING DIVISION CITY OF ANAHEIM BUILDING DEPARTMENT Z013 CALIFORNIA CODES 200 S. Anaheim Blvd., Suite 145 CODE. CYCLE Anaheim, CA 92805 01/01/2014 714 765-5153 EEF'ErmE DATE www.anaheim.net/building SMOKE DETECTORS AND CARBON MONOXIDE SELF CERTIFICATION Final Inspection approval will require this completed form to be on site along with the job card Permit Number: 054-71 Date: M /2S/2c�25 Project address: 3Z-I A 5? Property Owner: fI L� V I A So -SA Q(,.IRoZ The undersigned does hereby certify that I am the property owner of the above referenced property. I further certify that smoke alarms and carbon monoxide alarms are present and functional in all the following locations. All boxes must be checked below ,AT Smoke Alarms and Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedroom/s or in each hallway outside of the rooms. Z Smoke Alarms: In each room used for sleeping purposes. ,Z Smoke Alarm and Carbon Monoxide Alarm: In each story, including any habitable basement; (Note: in dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm and a carbon monoxide detector installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.) All dwelling units witpApched garages require carbon monoxide detectors. Signature: 02/2 �ZcZS California ResidentiOl Code (CRC) Section R314.6.2,CRC R315.2 States in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors when a building permit is issued for work on or in a building that is valued at $1,000 or more." CRC Section R314.3, CRC R315.2 defines required locations as indicted above. NOTE: This certification is only used when normal access to the interior of the dwelling by the City of Anaheim Inspector is not achieved during the course of project construction. It is normally used for exterior projects such as re -roofing, re -siding, patio covers, solar photovoltaic installations, and similar exterior construction work. 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax SEPT 2015 wYwv.anaheim.netlbuilding B842 Q y W_ c e {L ; J ° j T m � LL N O Z Q R J d o w N Q E N Z Crn LQL G N C J m a a a� a a J 'c O LL 0 6O N'2 z 7 4 P1001 Ng� Will a new main electrical service upgrade over 225 amps be installed and approved prior to this proposal? ❑ YesXNo Solar PV Standard Plan — Simplified Central!String Inverter Systems for One- and 7Wo-Family Dwellings 9. Single -Inverter Line Diagram u�em.«wesa. M� Flvnurxm�p �W MFl).MOY gYwMNUPA NARYv.Y.T �JwnMnn. iun mnp� ms�a�owo.o eernaoesmrr Awm ®.sema dW4 20 900024 25 8 1" ��— 7 VW 30 9 „•,,,,, ,,� .M nn ®bum ram¢n f69 C,wbch •CEC 690.a rm 2luly Nx�l vmaaam,.w..,..,,..,..,.-�..,.rw -...—__--.- - - 3 br plm rMtgoaes. Table 3 BranehI Breach Brmeh3 llm h4 Nume<r o(Mlcrdoverlen mACM 10 10 9 latev 11 Selected Condoetor Stan [Table 21(AWG) 10 10 10 Selected Braaebandlnvertm Oulw 20 20 20 OCPD UN.2 5. Solar Load Center (if used) 5.1 Solar Load Center is to have a bus bar rating less than 100 Amps. 5.2 Circuit Power see [STEP 11 = 8410 Watts 5.3 Circuit Current = (Circuit Power) / (AC voltage) = 30 _Amps Table 4 CYrc(A Cnips)SizeAWGurrent Clrceit Power (Watts) OCPD (Amps) � Cond) Minimum Metal Condon Size 24 5760 30 10 28 6720 35 8 1" 32 7"0 40 8 1" 36 8640 45 8 1" 40 9600 50 6 1w 48 11520 60 6 1" 56 13440 70 4 1 56" 64 15360 80 4 1 'A,• 72 17280 90 3 1 'A" 80 19M 100 3 1''A" 88 21120 110 2 1 56" 100 24000 125 1 2" 120 28M 150 1 /0 2" 140 33600 175 2/0 _ 2" 160 38400 200 hbk4 310 ,em-�•"^��^^•'^•,^^„^•"'H�oir®c.mrc 2» of 4T C(oo mnfloo •'CBC 690.E and 210.19(Axl)hamedio Table., muduaors v<roppa,mWamv mutt be 90'Cwo-n� w tmpaabnemdc in ft ukaldioa), 53 amain en *9 cmd,aom in reacularxxewey. 6. Point of Connection to Utility: 6.1 Load Side Connection only! Local utility does not allow for supply side connections 6.21s the P V OCPD positioned at the opposite end from input feeder location or main OCPD location or at either end of center fed panel. ®Yes (enter fed panel board) ❑ No (if no, submit through standard plan check process. 6.3 Per 705.12(D)(2): (Combined inverter Output OCPD size + Main OCPD size) <_ [bus bar size x (120%)] Bm Bar Sian (Amer) 100 125 125 200 225 225 400 600 B00 Main OCPD (Amps) too l0U 125 200 200 225 400 600 800 Maamam Combined loverter OCPn Min 1207. ofbw bar radag ,Amps) 20 50 25 40 65 45 BO 120 I60 Mndmum COmhised innrter OCPD with 1000/t of bus bar ratlag Am t � O> 0!=zan- ! =VOZ w_v;\ !$ ||\� ` "z°� E § a �i / � : zw / \ ^ ; / ) 8;W \. !e ■ Al \ / » z, / | 0 LLI: n!