529 S ANAHEIM BLVDPermit Types
BLD ELE MEC PLM
X
Permit Number: BLD2025-01545
Issued: 04/01/2025
www.anaheim.net/building
(714)765-4626
Quarter Section: 84
CITY OF ANAHEIM
BUILDING DIVISION
200 S. ANAHEIM BLVD.
(714) 765. 5153
Site Address: 529 S ANAHEIM BLVD ANAHEIM, CA 92805
Legal Description: N TR 16492 BLK LOT 21 LIN 23 TRACT 16492, LOT 21 OF
APN: 93881047
Project Description: Residential EV Charger Level 2
Living Ares: Number of Stoner.
Valuation: or'
Garage Area:
Construction Types:
Carport Area:
Occupancy Groups:
Balcony / Deck Area:
Fire Sprinklered:
Cool Roof:
Total Fees paid for Peonit: 177.00
People Associated with Project:
Contractor EV PROS INC
PO BOX 4220 COSTA MESA, CA 92626
Permit Applicant EV PROS INC
PO BOX 4220 COSTA MESA, CA 92628
Permit Applicant EV PROS INC
PO BOX 4220 COSTA MESA, CA 92628
Type Electrical Fixtures Qty Type
Plumbing Fixtures Qty Mechanical Fixtures Qty
EV Charger 1
The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the
date of permit Issuance. A new permit is required to commence or continue work.
PNPMEIM rq<
Cityof Anaheim OF iO
Building Division ' i
u >
-
�DVNOED ts�^
Do not occupy this building until the final inspections have been made.
FINAL INSPECTIONS
DATE
INSPECTOR
All applicable items below must be signed before utilities are released
Final Gas Test
Electrical Final
Plumbing Final
Mechanical Final
Cross Connection Control (714) 7654280
Engineering Final (714) 765-5126
INSPECTION
I DATE
I INSPECTOR
Fire Sprinkler (ONLY) (714) 765-5041
Do not pour concrete until the following applicable items have been signed:
Fire Dept. Final (714) 765-5041
Plumbing (Ground/Underfloor Drain Waste)
Water Engineering (714) 7654591
Electrical Ground Electrode/Ufer
Sub List/Bus. Lic. (714) 765.5194 (Allow 10 business days)
Setback/Forms/Trenches (Footings)
COA/Migation Measures
Do not install subfloor or pour floor slab until the follwing applicable items have been
sinned
Building Final (714 765.5153)
Last Inspection -Final Only After Above Completed
r
Plumbing (Ground/Underfloor Water)
Underfloor Rough Gas
PARTIAL INSPECTIONS
Building Inspections
Mechanical (Groundwork)
Electrical (Underground Conduit)
Pre -slab (Compaction/Membrane Reinf.)
Floor (JoistlGirders)
Underfloor Insulation (Raised Foundation Only)
Floor Nailing (Raised Foundation Only)
2nd Floor (Floor Nailing)
Do not cover or conceal the work below until the following applicable items have
been sioned
1st Floor Shear
Firesprinkler (Rough) (Fire Dept.)
Mechanical Inspections
2nd Floor Shear
Roof (Sheathing/Diaphragm/Frame)
Masonry (Reinf./Bond Beam/Pre-Grout)
Rough Plumbing (Top Out)
Rough Duct (Mechanical)
Rough Mechanical
Rough Electrical
Rough COA/Mitagation Measures
Plumbing Inspections
Framing (Only after Plbg., Ele., Mec. & Fire)
Insulation (Sound/Energy)
Do not tape or plaster until the following applicable items have been signed:
Drywall
Drywall Penetrations (Ele, Mec & Plbg)
Interior Lath
Exterior Lath
Electrical Inspections
Electrical Service Meter -(Meter will be set within 2-3
business days after approval) Excludes New
Exterior Plaster (Brown Coat)
T-Bar (Struct., Ele., or Mec.)
Grease Interceptor
(nn not harkfiVe' ne - )
Sewer
Water Engineering Backflow (Testable Only)
Water Service
T=SLn
7 = 5 L n
Gen 3 Wall Connector Manual
48A Single Phase
PRODUCT OVERVIEW
_,
This manual applies to Wall Connectors identified by part number 1457768-**-*
Product Specifications
Voltage and Wiring
Nominal 200-240 V AC single-phase
Current Output Range
12 - 48 amps
Terminal Blocks
12-4 AWG (3.5 - 25 mm2), copper only
Supported Conduit Sizing
3/4" (21 mm) default, 1" (27 mm) optional
Grounding Scheme
TN/TT
Frequency
50/60 Hz
Cable Length
8.5' (2.6 m) or 18' (5.5 m)
Wall Connector Dimensions
Height: 13.6" (345 mm)
Wire Box Bracket Dimensions
Width: 6.1" (155 mm)
Depth: 4.3" (110 mm)
Height: 9.8" (250 mm)
Width: 4.7" (120 mm)
Depth: 2.0" (50 mm)
Weight (including wirebox)
10 lb. (4.5 kg)
Operating Temperature
-22°F to 122°F (-30°C to 50°C)
Storage Temperature
-40 ° F to 185 ° F (-40 ° C to 85 ° C)
Enclosure Rating
Type 3R
Ventilation
Not required
Means of Disconnect
External branch circuit breaker
Ground Fault Circuit Interrupter
Integrated, no additional required (CCID20)
Wi-Fi
2.4 GHz, 802.11b/g/n
Agency Approvals
cULus - E351001
Transportation and storage: Ensure that Wall Connector is within storage temperature when moving,
transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
4 Gen 3 Wall Connector Manual
PRODUCT OVERVIEW
Circuit Breaker Rating / Maximum Output
Power Output
For maximum power output, install a standard double pole 60 amp circuit breaker. Wall Connector
includes integrated GFCI protection - do not install a GFCI circuit breaker.
Wall Connector incorporates automatic load management, which allows the max output to be
customized to an existing power supply. If the electrical supply is unable to support the 60 amp
configuration, select a lower amperage configuration.
Circuit breaker (amps)
60
50
40
30
20
15
Max output (amps)
48
40
32
24
16
12
Power output at 240 volts (kW)
11.5
9.6
7.6
5.7
3.8
2.8
NOTE: External disconnect switches are neither required nor recommended.
NOTE: Circuit breaker size is programmed during the commissioning process. See Commissioning
Procedure on page 22 for details.
NOTE: Some Tesla vehicles may draw less current than the max output. Actual charging rate depends on
Wall Connector output and onboard charger in the vehicle.
Branch Circuit Conductors and Ground Wire
• If installing for less than maximum power, refer to local electrical code to select correct conductors and
ground wire size that are suitable for the chosen circuit breaker.
• If installing for maximum power, use minimum 6 AWG, 900 C-rated copper wire for conductors.
NOTE: Upsize conductors if necessary.
• For sites with multiple Wall Connectors, each Wall Connector must have its own branch circuit with LI,
L2/N, and Ground.
• COPPER WIRE TERMINATIONS ONLY for landing in Wall Connector wirebox terminals. Conductors can
be stranded or solid.
• For outdoor installations, use watertight fittings when securing feeder wires to the wirebox.
Grounding Connections
Wall Connector must have a ground path back to the main equipment earthing point on site. Without a
proper ground connection, the Wall Connector will fault during a ground assurance test. Equipment -
grounding conductor must be run with the circuit conductors and connected to the equipment -
grounding terminal in the wirebox. Install a ground (PE) wire sized according to local electrical code.
Gen 3 Wall Connector Manual
INSTALLATION
Choosing Height
• Maximum height (indoor and outdoor): 60 in (1.52 m)
• Recommended height: -45 in (415 m)
• Minimum outdoor height: 24 in (0.6 m)
• Minimum indoor height: 18 in (0.45 m)
Maximizing Wi-Fi Signal Reception
Wall Connectors should be connected to a local Wi-Fi network for optimal functionality. For maximum
signal reception, avoid installing Wall Connector on opposite sides of concrete, masonry, metal studs,
and other physical obstructions that could impede Wi-Fi signal reception.
NOTE: If a mobile device is able to connect to local Wi-Fi at a given location, it is a good indication that
Wall Connector will also be able to connect.