Loading...
529 S ANAHEIM BLVDPermit Types BLD ELE MEC PLM X Permit Number: BLD2025-01545 Issued: 04/01/2025 www.anaheim.net/building (714)765-4626 Quarter Section: 84 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (714) 765. 5153 Site Address: 529 S ANAHEIM BLVD ANAHEIM, CA 92805 Legal Description: N TR 16492 BLK LOT 21 LIN 23 TRACT 16492, LOT 21 OF APN: 93881047 Project Description: Residential EV Charger Level 2 Living Ares: Number of Stoner. Valuation: or' Garage Area: Construction Types: Carport Area: Occupancy Groups: Balcony / Deck Area: Fire Sprinklered: Cool Roof: Total Fees paid for Peonit: 177.00 People Associated with Project: Contractor EV PROS INC PO BOX 4220 COSTA MESA, CA 92626 Permit Applicant EV PROS INC PO BOX 4220 COSTA MESA, CA 92628 Permit Applicant EV PROS INC PO BOX 4220 COSTA MESA, CA 92628 Type Electrical Fixtures Qty Type Plumbing Fixtures Qty Mechanical Fixtures Qty EV Charger 1 The permit shall expire by limitation and become null and void if the building or work has not passed final inspection 365 days from the date of permit Issuance. A new permit is required to commence or continue work. PNPMEIM rq< Cityof Anaheim OF iO Building Division ' i u > - �DVNOED ts�^ Do not occupy this building until the final inspections have been made. FINAL INSPECTIONS DATE INSPECTOR All applicable items below must be signed before utilities are released Final Gas Test Electrical Final Plumbing Final Mechanical Final Cross Connection Control (714) 7654280 Engineering Final (714) 765-5126 INSPECTION I DATE I INSPECTOR Fire Sprinkler (ONLY) (714) 765-5041 Do not pour concrete until the following applicable items have been signed: Fire Dept. Final (714) 765-5041 Plumbing (Ground/Underfloor Drain Waste) Water Engineering (714) 7654591 Electrical Ground Electrode/Ufer Sub List/Bus. Lic. (714) 765.5194 (Allow 10 business days) Setback/Forms/Trenches (Footings) COA/Migation Measures Do not install subfloor or pour floor slab until the follwing applicable items have been sinned Building Final (714 765.5153) Last Inspection -Final Only After Above Completed r Plumbing (Ground/Underfloor Water) Underfloor Rough Gas PARTIAL INSPECTIONS Building Inspections Mechanical (Groundwork) Electrical (Underground Conduit) Pre -slab (Compaction/Membrane Reinf.) Floor (JoistlGirders) Underfloor Insulation (Raised Foundation Only) Floor Nailing (Raised Foundation Only) 2nd Floor (Floor Nailing) Do not cover or conceal the work below until the following applicable items have been sioned 1st Floor Shear Firesprinkler (Rough) (Fire Dept.) Mechanical Inspections 2nd Floor Shear Roof (Sheathing/Diaphragm/Frame) Masonry (Reinf./Bond Beam/Pre-Grout) Rough Plumbing (Top Out) Rough Duct (Mechanical) Rough Mechanical Rough Electrical Rough COA/Mitagation Measures Plumbing Inspections Framing (Only after Plbg., Ele., Mec. & Fire) Insulation (Sound/Energy) Do not tape or plaster until the following applicable items have been signed: Drywall Drywall Penetrations (Ele, Mec & Plbg) Interior Lath Exterior Lath Electrical Inspections Electrical Service Meter -(Meter will be set within 2-3 business days after approval) Excludes New Exterior Plaster (Brown Coat) T-Bar (Struct., Ele., or Mec.) Grease Interceptor (nn not harkfiVe' ne - ) Sewer Water Engineering Backflow (Testable Only) Water Service T=SLn 7 = 5 L n Gen 3 Wall Connector Manual 48A Single Phase PRODUCT OVERVIEW _, This manual applies to Wall Connectors identified by part number 1457768-**-* Product Specifications Voltage and Wiring Nominal 200-240 V AC single-phase Current Output Range 12 - 48 amps Terminal Blocks 12-4 AWG (3.5 - 25 mm2), copper only Supported Conduit Sizing 3/4" (21 mm) default, 1" (27 mm) optional Grounding Scheme TN/TT Frequency 50/60 Hz Cable Length 8.5' (2.6 m) or 18' (5.5 m) Wall Connector Dimensions Height: 13.6" (345 mm) Wire Box Bracket Dimensions Width: 6.1" (155 mm) Depth: 4.3" (110 mm) Height: 9.8" (250 mm) Width: 4.7" (120 mm) Depth: 2.0" (50 mm) Weight (including wirebox) 10 lb. (4.5 kg) Operating Temperature -22°F to 122°F (-30°C to 50°C) Storage Temperature -40 ° F to 185 ° F (-40 ° C to 85 ° C) Enclosure Rating Type 3R Ventilation Not required Means of Disconnect External branch circuit breaker Ground Fault Circuit Interrupter Integrated, no additional required (CCID20) Wi-Fi 2.4 GHz, 802.11b/g/n Agency Approvals cULus - E351001 Transportation and storage: Ensure that Wall Connector is within storage temperature when moving, transporting, or storing. This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4 Gen 3 Wall Connector Manual PRODUCT OVERVIEW Circuit Breaker Rating / Maximum Output Power Output For maximum power output, install a standard double pole 60 amp circuit breaker. Wall Connector includes integrated GFCI protection - do not install a GFCI circuit breaker. Wall Connector incorporates automatic load management, which allows the max output to be customized to an existing power supply. If the electrical supply is unable to support the 60 amp configuration, select a lower amperage configuration. Circuit breaker (amps) 60 50 40 30 20 15 Max output (amps) 48 40 32 24 16 12 Power output at 240 volts (kW) 11.5 9.6 7.6 5.7 3.8 2.8 NOTE: External disconnect switches are neither required nor recommended. NOTE: Circuit breaker size is programmed during the commissioning process. See Commissioning Procedure on page 22 for details. NOTE: Some Tesla vehicles may draw less current than the max output. Actual charging rate depends on Wall Connector output and onboard charger in the vehicle. Branch Circuit Conductors and Ground Wire • If installing for less than maximum power, refer to local electrical code to select correct conductors and ground wire size that are suitable for the chosen circuit breaker. • If installing for maximum power, use minimum 6 AWG, 900 C-rated copper wire for conductors. NOTE: Upsize conductors if necessary. • For sites with multiple Wall Connectors, each Wall Connector must have its own branch circuit with LI, L2/N, and Ground. • COPPER WIRE TERMINATIONS ONLY for landing in Wall Connector wirebox terminals. Conductors can be stranded or solid. • For outdoor installations, use watertight fittings when securing feeder wires to the wirebox. Grounding Connections Wall Connector must have a ground path back to the main equipment earthing point on site. Without a proper ground connection, the Wall Connector will fault during a ground assurance test. Equipment - grounding conductor must be run with the circuit conductors and connected to the equipment - grounding terminal in the wirebox. Install a ground (PE) wire sized according to local electrical code. Gen 3 Wall Connector Manual INSTALLATION Choosing Height • Maximum height (indoor and outdoor): 60 in (1.52 m) • Recommended height: -45 in (415 m) • Minimum outdoor height: 24 in (0.6 m) • Minimum indoor height: 18 in (0.45 m) Maximizing Wi-Fi Signal Reception Wall Connectors should be connected to a local Wi-Fi network for optimal functionality. For maximum signal reception, avoid installing Wall Connector on opposite sides of concrete, masonry, metal studs, and other physical obstructions that could impede Wi-Fi signal reception. NOTE: If a mobile device is able to connect to local Wi-Fi at a given location, it is a good indication that Wall Connector will also be able to connect. m Gen 3 Wall Connector Manual