7630 E CORTO RD (5)City of Anaheim BUILDING DIVISION INSPECTION RECORD a SWIMMING POOL ADDRESS: 7630 E CORTO RD, ANAHEIM, CA 92808 OWNER: SHOWLE HIROKO PERMITS: SWI2023-00050 DATE ISSUED: 06/07/2023 DESCRIPTION: New Pool/Spa: Electrical for new above-groufid spa. POST THIS CARD WITH THE APPROVED PLANS IN A CONSPICUOUS PLACE ON THE JOB SITE Inspection Code Date Inspector 1. Main Drain 504 2. Electric Bonding 506 3. Steel 508 4. Approval to Gunite 510 DO NOT GUNITE POOUSPA until all the above Inspections have been signed. 5. BLD -Steel and Electric bonding (Rock Structures,Slides Etc) 508 DO NOT GUNITE ROCK STRUCTURE (water feature, rock slide, fountain, waterfall, grotto etc.) until the above Inspection has been signed. 6. Underground Electric 512 7. Gas Piping Test 514 8. P -Trap Receptor 516 9.fBackflow 518 1k, Deckf Eential & 520 DO NOT POUR FLATWORK until all the above inspections have been signed. 11. Rough Electrical 522 12. Fencing/Door Alarms 524 13. Plaster approval 526 DO NOT PLASTER until all the above inspections have been signed. 14. Final Electric 1 528 ' .V L,3 ' Sub -Contractors List MUST be approved and pool cover on site PRIOR to Pool Final Inspection request FINAL INSPECTION CODE DATE INSPECTOR 15. Rough Demo 527 16. Final 599 7Q 3 -('I$d MISC. INSPECTIONS Date Inspector fbidjobcards Inspec"ons 1.6: 1. All plumbing to be completed and the system pressurized to 35 lbs. with water or house pressure. 2. Ali metal within 5 feet of pool water, and all pool equipment, must be bonded to pool reinforcing steel with 6B solid copper wire. Niche light shell, deck inserts, etc. shall be bonded to pool rebar. 3. Pool equipment is not required to be set at this time. Inspeetlons 0.10: 1. Underground electric Inspected prior to backilling. 2. Gas line test at 100 for 15 minutes with 150 gauge. 3. when polyethylene gas piping Is used, a certificate from a certified Installer and tracer wire shall be provided per CPC 1210.1.7.2 APPENDIX I. Insaections 11.13: 1. Rough electric Inspection when all wiring Is completed and ready prior to the plastering of pool/spa. Potting compound in place at plastic light niche. 2. Current Code requires that any pool, spa or water feature contacting water 18 Inches at more In depth shall be enclosed by a bonier adequate to prevent entry of small children. The barrier shall comply with Sedion 3109 of current CBC and CRC APPDENDIX V specilytng the height of any fence provided as border to the pod d- shall be 60- above grade on the outside of the fence. 3. Doors from a garage shell meet the requirements for a gate. Glass windows within 5' of pool water shall be tempered glass. 4. Prior to pre -plaster inspection, streets, curbs and city sidewalks will be Inspected for any damage due to construction of pod or spas. ti. Grading complete with positive drainage to street or public way. All exposed plastic pipe shall be pointed to protect from sunlight Inspections 14.16: 1. Gas and Electrksl completely removed and 2x2 holes at bottom of pool and/or Isolated elements. 2. Pool backfilled: A.) with future build - sellvompactksg send 95% with receipt B.) No future build - any NI. 3. After pod is operating and in working condition with approved pod cover on $tie. INSPECTION REQUESTS Inspection requests made prior to 5:00 pm Monday - Friday will be scheduled on the following workday. To schedule your building Inspection online, please go to httpsJ/aca.ansheim.neUCitizenAccess Inspection can normally be reached between 7:30.8:00 A.M. (714)765.5153 4 0 To access your inspection timeframe: Please go to www.anaheim.net/building after 7,30am on the day of your Inspection. Under Online Services, dick on the link 'Inspection Timeframes- or call (714) 765.5153 + 0 Permit Number: SW12023-00050 Issued: 06/07/2023 www.anaheim.net/building (714)765.4626 Quarter Section: 209 Site Address: 7630 E CORTO RD, ANAHEIM, CA 92808 Legal Description: P BK 227 PG 40 PAR 1 APN:35614153 CITY OF ANAHEIM BUILDING DIVISION 200 S. ANAHEIM BLVD. (71411765-5153 Project Description: New Pool/Spa: Electrical for new above -ground spa. People Associated with Project: Permit Applicant PETER SHOWLER Owner SHOWLE HIROKO 7630 E CORTO RD OWNER - BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License State Law for the following reason(s) Indicated below by the checkmark(s) I have placed next to the applicable Item(s) (See. 7031.5 Business and Professlons Code: any city or county which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to Its Issuance, also requires the applicant for the permit to file a signed statement that he or she Is licensed pursuant to the provisions of the Contrectore' State License Law Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). as owner of property, or my employees with wages as their sole compensation, will do C_) all or"portions of the work, and the structure Is not `intended or offered for sale (Sec. 7044 Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal efforts, builds or Improves the property, provided that the Improvements are not Intended or offered for sale. If, however, the building or 0 I, as the owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044 Business and Professions Code: The Contractors' State License Lew does not apply to an owner of property who builds or Improves thereon, and who contracts for the projects with a licensed Contractor Dursuent to the Contractor's State Lt se Law). I am exempt from licensure under the ContractifirA State License Law for the following reason: & 2? Agent DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -Insure for worker's compensation, Issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. ❑ 1 have and will maintain worker's compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My worker's Compensation insurance carder and policy are: Cartier. Policy No.: Expiration Date: This section need not be completed If the permit Is for one hundred dollars ($100) or less. ❑ 1 certify that in the performance of the work for which this permit Is issued, t shall not employ any person in any manner so as to become subject to the worker's compensation laws of California, and agree that, N I should become subject to the worker's compensation provisions of Section 3700 of the Labor Code. I shall forthwith comDly with those orovisions. Date Signature of Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OR THE LABOR CODE. INTEREST. AND ATTORNEY'S FEES. I CONSTRUCTION LENDING AGENCY II LICENSED CONTRACTORS DECLARATION J I hereby affirm under penalty of perjury that there is a construction lending agency for the performance Lender's Information: I hereby certify that i have read this application and state that the Information above Is correct. I agree to comply with all city ordinances and state laws relating building construction, and hereby authorize representives of this city to enter upon the above mentioned property for inspection purposes. Date Signature of Applicant or Agen The premit shall expire by limitation and become null and void It the building or work has not passed final inspection 365 days from the date of permit issuance. A new permit is required to commence or continue work. I hereby affirm under penalty of perjury that I am licensed under provisions of chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. Date: 06/07/2023 Contractor: Number: SWI2023-00050 ' Expiration Date TYPE: Fees paid for Permit: $213.00